The rules should oblige the seller to give the purchaser an operating instrucion of APC SURT10000RMXLT-2TF5, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of APC SURT10000RMXLT-2TF5 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of APC SURT10000RMXLT-2TF5. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of APC SURT10000RMXLT-2TF5 should contain:
- informations concerning technical data of APC SURT10000RMXLT-2TF5
- name of the manufacturer and a year of construction of the APC SURT10000RMXLT-2TF5 item
- rules of operation, control and maintenance of the APC SURT10000RMXLT-2TF5 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of APC SURT10000RMXLT-2TF5 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of APC SURT10000RMXLT-2TF5, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the APC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of APC SURT10000RMXLT-2TF5.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the APC SURT10000RMXLT-2TF5 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
990-1216B 02/2004 User Manual English APC Smart APC Smart APC Smart APC Smart- - - -UP S UPS UPS UPS ® ® ® ® RT RT RT RT 7500/10000 VA 200 7500/10000 VA 200 7500/10000 VA 200 7500/10000 VA 200- - - - 240 VAC 6U 240 VAC 6U 240 VAC 6U 240 VAC 6U Tower/Rack Mount Tower/Rack Mount Tower/Rack Mount Tower/Rack Mount Uninterruptible Power Supply Unint[...]
-
Page 2
[...]
-
Page 3
1 Introduction The APC Smart-UPS RT is a high-performance, uninterruptible power system (UPS), designed to prevent blackouts, brownouts, sags and surges from reaching your com puters, servers, and other sensitive electronic equip ment. 1: I NST ALLA TION Attention: Re ad the safety i nformation sheet be fore installation. Unpacking Inspect the UPS [...]
-
Page 4
2 Hardwiring Attention: Wiring must be performed by a qualified electrician. 1. Install a utility circuit breaker in accordance with local electrical codes (see tables below) for input wiring only. 2. Switch the UPS input ci rcuit breaker (see A ) and utility circuit breakers OFF. 3. Remove the access panel (see B ). 4. Remove circular knocko uts. [...]
-
Page 5
3 7. XLI model only: For three-phase input, set the Input Phase Selector switch (see C ) to ‘3’. For single-phase input, leave switch in default position of ‘1’. 8. Switch the circuit breakers ON. 9. Check line voltages. 10. Replace the access panel. XLT/XLJ/XLTW M ODELS XLI M ODEL L1 L2 L1A L2A O UTPUT I NPUT O UTPUT I NPUT L1 L2 L3 N C B [...]
-
Page 6
4 Installing and Connecting the Batteries and Attaching the Front Bezel [...]
-
Page 7
5 C ONNECTING P OWER AND E QUIP MENT TO THE UPS 1. Hardwire the UPS (see Hardwiring ). 2. Connect equi pment to the UPS (cables not included for X LT/XLJ/XLTW m odels). 3. Turn on all connected equipm ent. To use the UPS as a m aster on/off switch, be sure that all connected equipm ent is switched ON. 4. Press the button on the front panel to power[...]
-
Page 8
6 B ASIC C ONNECTORS Serial Port Power management software and interface kits can be used with the UPS. Use only inter face kits suppli ed or approved b y APC. Ethernet Port Connect the UPS to the network . (Located on Web/SNMP card.) EPO Terminal The optional Emergency Power Off (EPO) feature allows connected loads to be immediately de-en ergized [...]
-
Page 9
7 2: O PERA TION F RONT D ISPLAY P ANEL Indicator Description Online The UPS is drawing utility power and performin g double conversion to sup ply power to connected equipm ent (see Troubl eshootin g ). On Battery The UPS is supplying battery powe r to the connected equipment. Bypass The UPS is in bypass mode, sending utility power directly to conn[...]
-
Page 10
8 Feature Function Normal /Bypass Manually switch connected eq uipment to bypass mode, so that utility power is sent directly to connected equipment. Battery op eration is not available while the UPS is in bypass mode. (See Troubleshooting. ) Cold Start This is not a normal condition. Supply immediate battery power to the UPS and connected equipm e[...]
-
Page 11
9 3: U SER C ONFIGURABLE I TEMS N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOFTWARE , W EB /SNMP CA RD , OPTIONAL S MA R T S LOT ACCESSORY CARDS OR T ER MINAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automatic Self-Test Every 14 days (336 hours) Every 7 d ays (168 hours), Every 14 days (336 hours), [...]
-
Page 12
10 N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOFTWARE , W EB /SNMP CA RD , OPTIONAL S MA R T S LOT ACCESSORY CARDS OR T ER MINAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION High Bypass Point +10% of output voltage setting +5%, +10%, +15%, +20% Maximum voltage that the UPS will pass to connected equipm[...]
-
Page 13
11 EPO (Emergency Power Off) Option The output power can be disabled i n an emergency by closing a s witch connected to the EPO. Adhere to national and loca l electrical codes when wiring. The switch should be connected in a normally open switch contact. External voltage is not required; the switch is driven by 12V internal supply. In closed condit[...]
-
Page 14
12 Terminal Mode to Configure UPS Parameters Terminal Mode is a menu driven interface that enables en hanced configuration of the UPS. Connect the serial cable to the serial port on the back of t he UPS. When using Po werChute ® Network Shut down software: 1. Open a t erminal pro gram. Exam ple: HyperT erminal • From the Desk top, go to Start =&[...]
-
Page 15
13 4: S TOR AG E , M AINTE NANCE , AND T RANSPORTING Storage Store the UP S covered a nd positi oned as for pro per functioni ng, in a cool , dry locatio n, with the batteries fully charged. (Bat teries must be c harged every six mont hs.) Store at: 0 -50,000 ft (0 - 15,000 m) 5 ° -113 ° F ( -15 - 45 ° C) Replacing the Battery Module(s) This UPS[...]
-
Page 16
14 5: T ROUBLESHOOTING Use the table below to solve minor installation and operation prob lems. Refer to the APC web site, www.apc.com , for assistance with complex UPS problems. P ROBLEM AND P OSSIBLE C AUS E S OLUTION UPS WILL NOT TURN ON Batteries are not connected properly. Check that the battery connectors are fully engage d. button not pushed[...]
-
Page 17
15 P ROBLEM AND P OSSIBLE C AUS E S OLUTION BYPASS LED ILLUMINATES The bypass switch has been turned on manually or through an accessory. If bypass is the chosen mode of ope ration, ignore the illuminated LED. If bypass is not the chosen mode of operation move the bypass switch on the back of the UPS, to the normal position. FAULT AND OVERLOAD LED [...]
-
Page 18
16 Service If the UPS requires service do not return it to the dealer. Instead, follow these steps: 1. Review t he problem s discussed in the Troubl eshooting section of t his manual to eliminate common pr oblems. 2. If the pr oblem persists, contact APC C ustomer Se rvice through t he APC we b site, www.apc.com /support . Note the m odel numbe[...]
-
Page 19
17 6: R EGULA T OR Y AND W ARRANTY I NFORMA TION Regulatory Agency Approvals and Radio Frequency Warnings 200, 208, 220, 230, 240 V MODELS This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take corrective actions. This equipment has been tested and found to comp[...]
-
Page 20
18 Declaration of Conformity[...]