Bryant PLUS 90X 353AAV manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bryant PLUS 90X 353AAV, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bryant PLUS 90X 353AAV one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bryant PLUS 90X 353AAV. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bryant PLUS 90X 353AAV should contain:
- informations concerning technical data of Bryant PLUS 90X 353AAV
- name of the manufacturer and a year of construction of the Bryant PLUS 90X 353AAV item
- rules of operation, control and maintenance of the Bryant PLUS 90X 353AAV item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bryant PLUS 90X 353AAV alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bryant PLUS 90X 353AAV, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bryant service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bryant PLUS 90X 353AAV.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bryant PLUS 90X 353AAV item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 353AA V Plus 90x 4 - - W ay Multipoise Condensing Gas Furnace Input Rates: 40,000 Only Pr oduct Data 4 - - W A Y MUL TIPOISE DESIGN ALLOWS MORE APPLICA TIONS A05085 A UNIQUE SEER SOLUTION The Plus 90x is an exciting addition to your product line. This high - - ef ficiency 4 - - way multipoise design furnace allows more applications while the ECM [...]

  • Page 2

    2 Direct or Non- - dir ect V enting —T h e Plus 90x can be installed as a 1 pipe/Non - - Direct vent (except 140 size unit and in manufactured/mobile home installations) or 2 pipe/Direct vent furnace. All direct vent Plus 90x models can be installed in a manufactured (mobile) home when the optional kit is used. This provides added flexibility to [...]

  • Page 3

    3 12 11 6 8 10 9 7 6 4 5 2 1 13 14 18 3 15 16 17 19 20 A08421 1. Burner sight glass for viewing burner flame. 2. Burner assembly (inside), operates with energy- - sav- ing, inshot burners and hot surface igniter for safe, dependable heating. 3. Combustion- - air intake connection to ensur e contam- inant- - free air (right or left side). 4. Redunda[...]

  • Page 4

    4 PHYSICAL DA T A **Note: 060- - 120 Sizes are phasing out.** UNIT SIZE 036040 036060 036080 048080 060100 060120 SHIPPING WEIGHT LB. (KG) 175 (47) 182 (57) 198 (64) 205 (69) 232 261 (74) LIMIT CONTROL SPST HEA TING BLOWER CONTROL (Off Delay) Solid - - - State Time Operation BURNERS (Monoport) 2 3 4 4 5 6 GAS CONNECTION SIZE 1/2 - - - in. NPT GAS V[...]

  • Page 5

    5 BR Y ANT ACCESSORIES* ACCESSORIES GAS CONVERSION KIT - - - NATURAL TO PROP ANE KGANP4601ALL GAS CONVERSION KIT - - - PROP ANE TO NA TURAL KGANP3901ALL MANUF ACTURED (MOBILE) HOME KIT KGAMH0301KIT DOWNFL OW BASE (For Combustible Floors) } KGASB0301ALL VENT TERMINA TION KIT (Bracket Only for 2 Pipes) 2 - - - IN. - - - KGAVT0101BRA 3 - - - IN. - - -[...]

  • Page 6

    6 A93086 CONCENTRIC VENT (DIRECT VENT/ 2-PIPE ONLY) A concentric vent kit allows vent and combustion-air pipes to terminate through a single exit in a roof or side wall. One pipe runs inside the other allowing venting through the inner pipe and combustion air to be drawn in through the outer pipe. A88202 DOWNFLOW SUBBASE One base fits all furnace s[...]

  • Page 7

    7 17 5 ⁄ 16 " 24 1 ⁄ 2 " 27 9 ⁄ 16 " TYP 27 5 ⁄ 8 " 29 1 1 ⁄ 16 " TY P 30 13 ⁄ 16 " 32 5 ⁄ 8 " TY P 33 1 ⁄ 4 " TYP CONDENSA TE DRAIN TRAP LOC A TION ( AL TERN A TE UPF LO W) 7 ⁄ 8 -IN . D IA ACCESSO R Y POWER ENT R Y 7 ⁄ 8 -IN. DIA POWER CONN CONDENS A TE DRAIN TRAP LOC A TION (D OWN FL O [...]

  • Page 8

    8 DOWNFLOW SUBBASE DIMENSIONS - - IN. (MM) FURNACE CASING WIDTH FURNACE IN DOWNFLOW APPLICATION PLENUM OPENING FL OOR OPENING HOLE NO . FOR WIDTH A D J U S T --- MENT A B C D 17-1/2 (445) Furnace with or without Cased Coil Assembly or Coil Box 15 - - - 1/8 (384) 19 (483) 16-3/4 (425) 20 - - - 3/8 (518) 3 21 (533) Furnace with or without Cased Coil [...]

  • Page 9

    9 CONDENSA TE TRAP A93026 MEDIA FIL TER CABINET A Media Filter Cabinet AB 16" (406) 17" (432) 16" (406) 20" (508) 21" (533) 20" (508) 24" (610) 25" (635) 24" (610) 23 5 / 8 " (600 mm) 23 3 / 8 " (594 mm) F u rnace Side 23 3 / 4 " (603 mm) Centerline Screw Slots 25 5 / 8 " (651 mm) Duc[...]

  • Page 10

    10 CLEARANCE T O COMBUSTIBLES 335122-201 REV . B LIT TOP A08435 353AAV[...]

  • Page 11

    11 PERFORMANCE DA T A EFFICIENCY UNIT SIZE 036040 036060 036080 048080 060100 060120 CAP ACITY* Direct V ent (2 - - - pipe) (Shaded capa cities are specified on the rating plate) Upflow 38000 56000 75000 75000 94000 113000 Downflow 38000 56000 75000 75000 94000 113000 Horizontal 38000 56000 74000 75000 93000 112000 CAP ACITY* Non - - - Direct vent [...]

  • Page 12

    12 AIR DELIVER Y—CFM (WITH F IL TER) EXTERNAL STATIC PRESSURE (in.w c) UNIT SIZE RETURN-AIR SUPPLY SPEED 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 5(Gry) 1425 1385 1350 1305 1260 1210 1165 1100 995 855 4(Yel) 1215 1165 1130 1085 1025 970 905 840 795 730 3(Blu) 1060 1005 960 910 845 790 715 660 610 560 2(Org) 890 835 770 695 640 570 510 450 355 235 03[...]

  • Page 13

    13 COMBUSTION - -AIR AND VENT PIPING FOR DIRECT VENT/2 - -PIPE (ALL SIZES) AND NON - - DIRECT VENT/1 - - PIPE (SIZES 040 THROUGH 120 ONL Y) APPLICA TIONS AL TITUDE FT (M ) UNIT SIZE (BTUH) DIRECT VENT (2 -PIPE) ONL Y NON-DIRECT VENT (1-PIPE) ONL Y NUMBER OF 90 ° ELBOWS TERMINATION TYPE PIPE DIA IN. (mm)* PIPE DIA IN. (mm)* 1 2 3 4 5 6 0 to 2000 (0[...]

  • Page 14

    14 COMBUSTION - -AIR AND VENT PIPING FOR DIRECT VENT/2 - -PIPE (ALL SIZES) AND NON - - DIRECT VENT/1 - - PIPE (SIZES 040 TH ROUGH 120 ONL Y) APPLICA TIONS (CON’T .) AL TITUDE FT (M ) UNIT SIZE (BTUH) DIRECT VENT (2 -PIPE) ONL Y NON-DIRECT VENT (1-PIPE) ONL Y NUMBER OF 90 ° ELBOWS TERMINATION TYPE PIPE DIA IN (mm)* PIPE DIA IN (mm)* 1 2 3 4 5 6 3[...]

  • Page 15

    15 COMBUSTION - -AIR AND VENT PIPING FOR DIRECT VENT/2 - -PIPE (ALL SIZES) AND NON - - DIRECT VENT/1 - - PIPE (SIZES 040 TH ROUGH 120 ONL Y) APPLICA TIONS (CON’T .) AL TITUDE FT (M ) UNIT SIZE (BTUH) DIRECT VENT (2 -PIPE) ONL Y NON-DIRECT VENT (1-PIPE) ONL Y NUMBER OF 90 ° ELBOWS TERMINATION TYPE PIPE DIA IN. (mm)* PIPE DIA IN. (mm)* 1 2 3 4 5 6[...]

  • Page 16

    16 COMBUSTION - -AIR AND VENT PIPING FOR DIRECT VENT/2 - -PIPE (ALL SIZES) AND NON - - DIRECT VENT/1 - - PIPE (SIZES 040 TH ROUGH 120 ONL Y) APPLICA TIONS (CON’T .) AL TITUDE FT (M ) UNIT SIZE (BTUH) DIRECT VENT (2 -PIPE) ONL Y NON-DIRECT VENT (1-PIPE) ONL Y NUMBER OF 90 ° ELBOWS TERMINATION TYPE PIPE DIA IN. (mm)* PIPE DIA IN. (mm)* 1 2 3 4 5 6[...]

  • Page 17

    17 COMBUSTION - -AIR AND VENT PIPING FOR DIRECT VENT/2 - -PIPE (ALL SIZES) AND NON - - DIRECT VENT/1 - - PIPE (SIZES 040 TH ROUGH 120 ONL Y) APPLICA TIONS (CON’T .) AL TITUDE FT (M ) UNIT SIZE (BTUH) DIRECT VENT (2 -PIPE) ONL Y NON-DIRECT VENT (1-PIPE) ONL Y NUMBER OF 90 ° ELBOWS TERMINATION TYPE PIPE DIA IN. (mm)* PIPE DIA IN. (mm)* 1 2 3 4 5 6[...]

  • Page 18

    18 MAXIMUM ALLOW ABLE EXP OSED VENT PIPE LENGTH - - FT (M) WITH AND WITHOUT INSULA TION IN WINTER DESIGN TEMPERA TURE AMBIENT* FURNACE SIZE WINTER DESIGN TEMPERA TURE ° F 〈° C) MAX PIPE DIAMETER IN (mm) WITHOUT INSULA TION FT (M ) WITH 3/8–IN. OR THICKER INSULA TION† FT (M ) 040 20 ( - - - 7) 1.5 (38) 51 (16) 70 (21) 0 ( --- 1 8 ) 1.5 (38) [...]

  • Page 19

    19 ELECTRICAL DA T A UNIT SIZE 036040 036060 036080 048080 060100 060120 U N I T V O L T S --- H E R T Z --- P H A S E 1 1 5 --- 6 0 --- 1 1 1 5 --- 6 0 --- 1 1 1 5 --- 6 0 --- 1 1 1 5 --- 6 0 --- 1 1 1 5 --- 6 0 --- 1 1 1 5 --- 6 0 --- 1 MAXIMUM UNIT AMPS 8 9.4 9.4 9.6 12.1 12.1 UNIT AMP ACITY 10.8 12.5 12.5 12.8 15.9 15.9 MINIMUM WIRE SIZE 14 14 [...]

  • Page 20

    20 TYPICAL INST ALLA TIONS COMBUSTION AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) A/C COIL OUTDOOR UNIT VENT PIPE HUMIDIFIER GAS-FIRED WATER HEATER ELECTRONIC AIR CLEANER AIRFLOW FRONT OF FURNACE COMBUSTION AIR INLET (NON-DIRECT 1-PIPE APPLICATION) A05064 Upflow Application ELECTRONIC AIR CLEANER HUMIDIFIER A/C COIL VENT COMBUSTION AIR (DIRECT VENT/ [...]

  • Page 21

    21 TYPICAL INST ALLA TIONS (CONTINUED) COMBUSTION–AIR PIPE ELECTRONIC AIR CLEANER FURNACE CONDENSATE DRAIN REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW VENT PIPE FRONT OF FURNACE DIRECT VENT/2-PIPE APPLICATION) COMBUSTION-AIR INLET (NON-DIRECT VENT/1-PIPE APPLICATION) A05066 Attic - - Horizontal Application COMBUSTION– AIR PIPE (DIRECT VE[...]

  • Page 22

    22 GUIDE SPECI FICA TIONS Plus 90x Single - - Stage/Deluxe Gas Furnace 353AA V GENERAL System Description Furnish a _________________ (4 - - way multipoise) fixed capacity gas- - fired condensing furnace for use with natural gas or propane (factor y authorized conversion kit r equired for propane); furnish cold air return plenum; furnish external m[...]