Delta 66-202 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Delta 66-202, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Delta 66-202 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Delta 66-202. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Delta 66-202 should contain:
- informations concerning technical data of Delta 66-202
- name of the manufacturer and a year of construction of the Delta 66-202 item
- rules of operation, control and maintenance of the Delta 66-202 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Delta 66-202 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Delta 66-202, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Delta service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Delta 66-202.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Delta 66-202 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INSTRUCTIO N M AN UAL P ART NO. D26316 Rev .0 Copyright © 2002 Delta Machinery T o learn more about DEL T A MACHINER Y visit our website at: www .deltamachinery .com. For Parts, Service, W arranty or other Assistance, please call 1-866-422-4286. Oil-Fr ee Air Compr essor (66-202) ESP AÑOL: PÁGINA 25 FRANÇAIS: P AGE 49[...]

  • Page 2

    2- ENG D26316 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, may result in minor [...]

  • Page 3

    3- ENG D26316 IMPORT ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this pr oduct could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fir e How T o Prevent It What Could Happen It is nor[...]

  • Page 4

    4- ENG D26316 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury . How T o Prevent It What Could Happen WARNING: Risk fr om Flying Objects HOW TO PREVENT IT WHA T CAN HAPPEN The compressed air stream can cause s[...]

  • Page 5

    5- ENG D26316 HOW TO PREVENT IT WHA T CAN HAPPEN WARNING: Risk to Br eathing WARNING: Risk of Electrical Shock HOW TO PREVENT IT WHA T CAN HAPPEN HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used pr operly it may cause electric shock. Repairs attempted by unqualified personn[...]

  • Page 6

    6- ENG D26316 HOW TO PREVENT IT WHA T CAN HAPPEN WARNING: RISK OF BURNS T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will r emain hot for several minutes after operation. Do not reach ar ound prote[...]

  • Page 7

    7- ENG D26316 Review and understand all instructions and war nings in this manual. Become familiar with the operation and controls of the air compr essor . Keep operating area clear of all persons, pets, and obstacles. Keep children away fr om the air compressor at all times . Do not operate the product when fatigued or under the influence of alcoh[...]

  • Page 8

    8- ENG D26316 GLOSSAR Y Become familiar with these terms before operating the unit. CFM : Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measur e of air delivery . PSIG: Pounds per square inch gauge; a unit of measur e of pressure. Code Certification: Products that bear one or mor e of the following marks: UL, CUL, ETL, CETL[...]

  • Page 9

    INST ALLA TION Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated ar ea. The air compressor should be located at least 12" away fr om the wall or other obstructions that will interfere with the flow of air . The air compr essor pump and shroud ar e designed to allow for proper cooling. The ventilation [...]

  • Page 10

    10- ENG D26316 V oltage and Circuit Pr otection Refer to the Parts Manual for the voltage and minimum branch circuit requir ements. Certain air compressors can be operated on a 15 amp cir cuit if the following conditions are met. 1. V oltage supply is 108V -132V AC at the outlet. 2. Circuit is not used to supply any other electrical needs (lights, [...]

  • Page 11

    11- ENG D26316 OPERA TION Know Y our Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERA TING YOUR UNIT . Compar e the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for futur e refer ence. Description of Operation Become familiar with these controls b[...]

  • Page 12

    12- ENG D26316 Before Starting Break-in Pr ocedure Serious damage (for units with a tank) may result if the following break-in instructions ar e not closely followed. This procedur e is required befor e the air compressor is put into service and when the check valve or a complete compressor pump has been r eplaced. 1. Make sure the On/Auto/Of f lev[...]

  • Page 13

    13- ENG D26316 MAINTENANCE Customer Responsibilities Daily or after each use Before each use Check Safety V alve ● Drain T ank ● T o Check Safety V alve If the safety valve does not work properly , over - pressurization may occur , causing air tank ruptur e or an explosion. Before starting compr essor , pull the ring on the safety valve to make[...]

  • Page 14

    14- ENG D26316 T o Replace or Clean Check V alve 1. Release all air pressur e from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug unit. 3. Loosen the nut on the outlet tube and move the outlet tube to the side. 4. Unscrew the check valve (turn counterclockwise) using a socket wr ench. 5. Make sure the valve disc mov[...]

  • Page 15

    15- ENG D26316 T o Replace Regulator 1. Release all air pressur e from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Using an adjustable wrench r emove the gauges and hose from the regulator . 4. Remove the regulator . 5. Apply pipe sealant tape to the nipple on the standpipe. 6. Assemble the regulator a[...]

  • Page 16

    16- ENG D26316 Performing repairs may expose voltage sour ces, moving parts or compressed air sour ces, moving parts or compressed air sour ces. Personal injury may occur . Prior to attempting any repairs, unplug the air compr essor and bleed off all air tank air pressur e. PROBLEM CAUSE CORRECTION Pressur e switch does not shut off motor when comp[...]

  • Page 17

    17- ENG D26316 Regulator will not shut off air outlet. Damaged regulator . Replace. PROBLEM CAUSE CORRECTION It is normal for "some" pressur e drop to occur . If there is an excessive amount of pressur e drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph i[...]

  • Page 18

    18- ENG D26316 PROBLEM CAUSE CORRECTION Motor will not run. Check fuse box for blown fuse and replace as necessary . Reset circuit breaker . Do not use a fuse or circuit br eaker with higher rating than that specified for your particular branch circuit. Check for proper fuse. Y ou should use a time delay fuse. Check for low voltage problem. Check t[...]

  • Page 19

    19- ENG D26316 NOTES[...]

  • Page 20

    20- ENG D26316 AIR COMPRESSOR DIAGRAM 17 18 16 13 14 12 11 10 15 8 7 4 5 6 9 1 2 3 19[...]

  • Page 21

    21- ENG D26316 P ARTS LIST Key No Part Number Description 1 H-2099 Adapter 2 Z-GA-369 Pressur e Gauge 3 CAC-4296-1 Regulator 4 SS-1286 Nipple 5 SSP-6021 Bushing Reducer 6 D20114 Safety V alve 7 Z-DAC-4105-2 Pressur e Switch 8 SSP-480 Nipple 9 SSW-7480 Strain Relief Bushing 10 SSW-7367 Strain Relief Bushing 11 SUDL-403-1 Power Cord Assembly 12 AC-04[...]

  • Page 22

    22- ENG D26316 AIR COMPRESSOR PUMP DIAGRAM 1 15 20 14 16 13 12 7 4 10 11 9 8 6 5 3 21 2 18[...]

  • Page 23

    23- ENG D26316 P ARTS LIST Key No Part Number Description 1 AC-0471 Shroud, Left 2 AC-0470 Shroud, Right 3 CAC-1196 Cylinder Head 4 * CAC-1212 T ube Seal 5 * CAC-1199 Gasket Head 6 Z-D24985 V alve Plate Assembly 7 DAC-269 Outlet T ube 8 * SSG-8169 O-ring 9+ ————— Rod Assembly 10 CAC-1206-1 Hose Clamp 11 AC-0206 Isolator T ube 12 x SSF-314[...]

  • Page 24

    24- ENG D26316 LIMITED W ARRANTY DEL T A MACHINERY warrants to the original purchaser that all pr oducts covered under this warranty are free from defects in material and workmanship. Products cover ed under this warranty include air compressors, air tools, service parts, pressure washers, and generators, which have the following warranty periods: [...]