Go to page of
Similar user manuals
-
Water Pump
Franklin 5870206300
28 pages 2.11 mb -
Water Pump
Franklin DDS Series
8 pages 0.13 mb -
Water Pump
Franklin TS-TPI
48 pages 0.39 mb -
Water Pump
Franklin S - J Series
8 pages 0.2 mb -
Water Pump
Franklin TB1CI
44 pages 1.72 mb -
Water Pump
Franklin TB2CI
44 pages 1.72 mb -
Water Pump
Franklin 2007
75 pages 2.5 mb -
Water Pump
Franklin DDD Series
8 pages 0.13 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Franklin 5870206300, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Franklin 5870206300 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Franklin 5870206300. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Franklin 5870206300 should contain:
- informations concerning technical data of Franklin 5870206300
- name of the manufacturer and a year of construction of the Franklin 5870206300 item
- rules of operation, control and maintenance of the Franklin 5870206300 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Franklin 5870206300 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Franklin 5870206300, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Franklin service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Franklin 5870206300.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Franklin 5870206300 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Constant Pr essur e W ater System S ub D rive 300 Installation Manual[...]
-
Page 2
2 Contents Description and Features ................................................................................ 4 Included Items .................................................................................................. 5 How It W orks .....................................................................................................[...]
-
Page 3
3 T able 1: SubDrive Models Model Name Part Number Use with Motor Series SubDrive300 5870206300 (NEMA 4) 234 317 xxxx (5.0 Hp)[...]
-
Page 4
4 Description and Featur es The Franklin Electric SubDrive300 is a dependable residential and light commercial water system contr oller that uses advanced electronics to enhance the performance of standard submersible pumps. When used with the speci fi ed Franklin Electric motor (see T able 1), the SubDrive eliminates pressur e cycling associated [...]
-
Page 5
5 Included Items A. Controller Unit B. Strain Relief Fittings C. Pressur e Shut-off Sensor and Boot D. Pr essure Sensor and Boot Franklin Ele ctri c is n ow o f fer ing an int rod uct ory warran ty exte nsion on S ubDriv e 75, Sub Driv e 150 and M onoDr ive. The ex ten ded war ran ty i s f ree, bu t the Su bDriv e/M ono - Driv e must be registered [...]
-
Page 6
6 How It W orks The Franklin Electric SubDrive300 is designed to be part of a system that consists of only four components: A. Standard Pump and Franklin Electric Motor . B. SubDrive Controller . C. Small Pressur e T ank (for tank size, see T able 3). D. Franklin Electric Pressure Sensor (pr ovided). E. Franklin Electric Pressur e Shut-Off Sensor ([...]
-
Page 7
7 Motor Soft Start Normally , when there is a demand for water , the SubDrive300 will be operating to accurately maintain system pressur e. Whenever the SubDrive300 detects that water is being used, the controller always “ramps up” the motor speed while gradually increasing voltage, r esulting in a cooler motor and lower start-up current compar[...]
-
Page 8
8 Pump Sizing The SubDrive300 is con fi gur ed at the factory for use with 3 Hp pumps that are mounted to 5 Hp Franklin Electric thr ee-phase motors. In general, the SubDrive300 will enhance the performance of a 3 Hp pump to a similar or better performance than a conventional 5 Hp pump of the same fl owrating (pump series). T o select the proper [...]
-
Page 9
9 Underload Sensitivity for Shallow W ells The SubDrive300 controller is con fi gured at the factory to ensur e detection of Underload faults in a wide variety of pumping applications. In rare cases (as with certain pumps in shallow wells) this trip level may result in nuisance faults. If the pump is installed in a shallow well, activate the contr[...]
-
Page 10
10 ▲ WARNING ! Serious or fatal electrical shock may result fr om failure to connect the ground terminal to the motor , SubDrive controller , metal plumbing, or other metal near the motor or cable, using wire no smaller than motor cable wir es. T o minimize risk of electrical shock, disconnect power before working on or around the SubDrive300 sys[...]
-
Page 11
11 Contr oller Location Selection The SubDrive controller is intended for operation in ambient temperatur es up to 125°F (51°C) at 230 V AC input. The following r ecommendations will help in selection of the proper location of the SubDrive unit: 1. A tank tee is recommended for mounting the tank, pr essure sensor , pressur e gauge, and pressur e [...]
-
Page 12
12 4. For indoor or outdoor installations. 5. The SubDrive300 should only be mounted with the wiring end oriented downward. The contr oller should not be placed in direct sunlight or other locations subject to direct rain or snow . 6. The mounting location should have access to 230 V AC electrical supply and to the submersible motor wiring. T o avo[...]
-
Page 13
13 Cir cuit Breaker and Wir e Sizing The minimum circuit br eaker size and maximum allowable wire lengths for connection of motor to the SubDrive300 are given in the following table: A 10-foot section of cable is provided with the SubDrive300 to connect the pressur e sensors. NOTE: • Maximum allowable wire lengths ar e measured between the contro[...]
-
Page 14
14 Pow er Supply Fr om Circuit Breaker* Quick Refer ence Guid e P/N 587 020 6300 P u Fr a El e M o PRESSURE SENSOR SHUT-OFF INT FAN INV FAN PFC FAN NO NO COM RELAY SW2 SW1 O N Congur a 1 OFF ON Outp u From P ower Sourc e L1 L2 (Input) * Note : T o avoid possible interference with other appliances, please refer to the enclosed installation guide [...]
-
Page 15
15 e SubDrive300 (not to scale) T ank Precharge Ination Valve Pressur e Gauge Pressur e Sensor T o Residence Pressure S witch Set Point (PSI) 25 30 35 40 45 55 60 65 70 75 80 Pressure T ank Pre-Charge (PSI) 18 21 25 28 32 35 39 42 46 49 53 56 Pressur e Setting Guide 50 (F actory set) Pressur e Relief V alve Discharge into drain rated for max pum[...]
-
Page 16
16 Pr essure T ank The SubDrive needs only a small pressur e tank to maintain constant pressur e (see table below for recommended tank size). For pumps rated 12 gpm or more, a slightly lar ger tank is r ecommended for optimum pressur e regulation. The SubDrive can also use an existing tank with a much lar ger capacity . T able 3: Minimum Pressur e [...]
-
Page 17
17 Installation Pr ocedure 1. Disconnect electrical power at the main breaker . 2. Drain the system (if applicable). 3. Install the pressur e sensor and pressur e shut-off sensor at the pressur e tank tee downstream of the pr essure tank (the pr essure tank should be between the pressur e sensor and the pump). The sensors have a ¼-18 National Pipe[...]
-
Page 18
18 Wiring Connections 1. V erify that the power has been shut off at the main breaker . 2. V erify that the dedicated branch circuit for the SubDrive300 is equipped with a properly-sized cir cuit breaker . Refer to T able 2 (Page 13) for minimum breaker size. 3. Use the appropriate strain r elief or conduit connectors. T ype B liquid tight fi ttin[...]
-
Page 19
19 6. Feed the 230 V AC power leads thr ough the bottom left side of the SubDrive300 controller and connect them to the terminals marked L1, L2, and GND (Figure 3). A 10-foot section of pr essure sensor cable is pr ovided with the controller , but it is possible to use similar 22 AWG wire for distances up to 100 feet from the pr essure sensor . A 1[...]
-
Page 20
20 10A. Connect the other end of the pressure sensor cable with the two spade terminals to the pressur e sensor . The connections are interchangeable (Figur e 4A). 10B. Connect the other end of the pr essure sensor cable with the two ¼" quick connect terminals to the pressur e shut-off sensor . The connections are inter changeable (Figure 4B)[...]
-
Page 21
21 Start-Up and Operation Apply power to the controller . A steady green light indicates that the SubDrive300 has power but the pump is not running. The green light will fl ash continuously when the pump is running. Leaky Systems Leaky water systems might keep the controller running due to the accurate pressur e sensing capability of the pressur e[...]
-
Page 22
22 NOTES: (A) Operating temperature is speci fi ed at full output power when installed as described in Controller Location Selection on Page 11. (B) Refer to Page 23 for detailed mounting dimensions. (C) If a pump other than the default rating is used, refer to Page 8 for drive con fi guration. Input from Power Source (single-phase) V oltage 190-[...]
-
Page 23
23 Mounting Dimensions 14.75” 12.00” 15.34” 8.75” 4.75”[...]
-
Page 24
24 Diagnostic Fault Codes Should an application or system problem occur , built-in diagnostics will protect the system. The r ed “F AUL T” light on the front of the SubDrive300 controller will fl ash a given number of times to indicate the nature of the fault. In some cases, the system will shut itself off until corr ective action has been tak[...]
-
Page 25
25 System T roubleshooting Guide Symptom Possible Cause Corrective Action W ater fl ow rate is not as high as expected. Motor is running backwards. V erify motor connections. See Figure 2 in the “Wiring Connections” section. T emperature in the controller is too high. If the controller’ s heat exchanger becomes too hot, the controller will r[...]
-
Page 26
26 Underload Smart Reset If a motor Underload fault condition occurs, the most likely cause is an overpumped or dry well. T o allow the well to recover , the SubDrive300 controller will wait 30 seconds to 5 minutes, determined by duration of the previous run time, befor e restarting the motor . For example, the fi rst time the fault occurs, the co[...]
-
Page 27
TOLL-FREE HELP FROM A FRIEND Franklin Electric Submersible Service Hotline 800-348-2420[...]
-
Page 28
400 E. Spring Street Bluffton, IN 46714 Tel: 260-824-2900 Fax: 260-824-2909 www.franklin-electric.com M1491 11.05 225286101 Rev. 1[...]