Franklin Water Pump manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Franklin Water Pump, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Franklin Water Pump one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Franklin Water Pump. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Franklin Water Pump should contain:
- informations concerning technical data of Franklin Water Pump
- name of the manufacturer and a year of construction of the Franklin Water Pump item
- rules of operation, control and maintenance of the Franklin Water Pump item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Franklin Water Pump alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Franklin Water Pump, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Franklin service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Franklin Water Pump.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Franklin Water Pump item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    OWNERS MANUAL INST ALLA TION • OPERA TION • MAINTENANCE 6” & 8” SUBMERSIBLE TURBINE PUMPS BE SURE T O READ OWNER’S MANUAL CAREFULL Y BEFORE INST ALLING YOUR PUMP .[...]

  • Page 2

    CONTENTS Inspection-Receipt of Equipment....................................................... Equipment and Installation Record................................................. General Information........................................................................ Suitability of the Well........................................................[...]

  • Page 3

    B. EQUIPMENT INST ALLA TION RECORD *Record the following details at the time of the installation and retain for future references: A. INSPECTION-RECEIPT OF EQUIPMENT Examine equipment at the time of receipt. Check that the power cable is not cut or damaged, and that all equipment is correct for the installation. Handle the pump, cable and motor car[...]

  • Page 4

    C. GENERAL INFORMA TION D. SUIT ABILITY OF THE WELL Submersible Pumps as well as all water pumps, are designed to handle clean, cool, clear water . Water from an undeveloped well often contains excessive amounts of sand, dirt and other abrasives which can cause damage to the pump. Install the pump in a well which has already been properly developed[...]

  • Page 5

    *CAUTION* T AKE CARE TO PREVENT DAMAGE TO THE CABLE DURING THE INST ALLA TION. F . ELECTRICAL INST ALLA TION When the cable is supplied on a reel, support the reel on a piece of pipe laid across a pair of sturdy saw horses. Locate the reel about 6 ft. from the well so that the cable unwinds from the top. Prevent the cable from scraping on the well [...]

  • Page 6

    ELECTRICAL INST ALLA TION & TESTS Employ a competent electrician to do the wiring in accordance with local electrical codes. Conventional overhead or underground installation is satisfactory for the electrical power transmission to the Well Head. Check that the power supply corresponds with that shown on the name plates of the motor and control[...]

  • Page 7

    Check that the currents in the individual phases of a 3-phase system are approximately equal. Where there is considerable difference between them, change all 3 connections at the starter as shown below (so that rotation remains the same) to obtain the most consistent readings. Starter L1 L2 L3 cable (1) black yellow red cable (2) red black yellow c[...]

  • Page 8

    FLOA TLESS LIQUID LEVEL CONTROL The sensing elements of a fl oatless liquid level control consists of 2 electrodes suspended in the well by insulated wires. These wires connect to a relay which serves as a pilot switch to the starting equipment. The lower electode is set just above the pump, and the upper at some distance below the static water le[...]

  • Page 9

    U.S. LIMITED W ARRANTY* Franklin Pump Systems, Inc. Franklin Pump Systems, Inc. warrants its new products to be free of defects in material and workmanship for a period of 1 year from date of installation or 2 years from date of manufacture, whichever comes fi rst, WHEN installed in a domestic water systems application and pumping potable water on[...]

  • Page 10

    [...]

  • Page 11

    [...]

  • Page 12

    E-631 5/05 12401 Interstate 30 • P .O. Box 8903 Little Rock, AR 72219[...]