Go to page of
Similar user manuals
-
Switch
Generac Power Systems 09227-0
20 pages 1.42 mb -
Switch
Generac Power Systems R-200A
16 pages 0.28 mb -
Switch
Generac Power Systems 004945-1
20 pages 0.85 mb -
Switch
Generac Power Systems Digital Controller R-200A
16 pages 0.29 mb -
Switch
Generac Power Systems 5464
2 pages 0.9 mb -
Switch
Generac Power Systems 004678-2
20 pages 0.84 mb -
Switch
Generac Power Systems 09229-0
20 pages 1.42 mb -
Switch
Generac Power Systems 005036-0
20 pages 0.85 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Generac Power Systems 09227-0, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Generac Power Systems 09227-0 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Generac Power Systems 09227-0. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Generac Power Systems 09227-0 should contain:
- informations concerning technical data of Generac Power Systems 09227-0
- name of the manufacturer and a year of construction of the Generac Power Systems 09227-0 item
- rules of operation, control and maintenance of the Generac Power Systems 09227-0 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Generac Power Systems 09227-0 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Generac Power Systems 09227-0, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Generac Power Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Generac Power Systems 09227-0.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Generac Power Systems 09227-0 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
PO WER SY STEMS, INC. ® Owner’ s Man ual 100 and 200 Amp “V” T ype and “Y” T ype T ransfer Switch Models: 09227-0, 09228-0, 09229-0, and 09230-0 This manual should remain with the unit.[...]
-
Page 2
Generac ® Pow er Systems, Inc. Generac cannot possibly anticipate every possible cir cumstance that might involve a hazard. The warn- ings in this manual, and on tags and decals affixed to the unit are, therefore, not all-inclusive. If you use a procedure, work method or operating tech- nique Generac does not specifically recommend, you must satis[...]
-
Page 3
T able of Contents Generac ® Pow er Systems, Inc. 1 Safety Rules ..........................................Inside Front Cover Section 1 — General Information ..................................2 1.1 Introduction ............................................................2 1.2 Equipment Description ..........................................2 1.3 [...]
-
Page 4
2 Generac ® Pow er Systems, Inc. Sectio n 1 — General Information Generac “V” T ype and “Y” T ype T ransfer Switch 1.1 I NTRODUCTION This manual has been prepared especially for the purpose of familiarizing personnel with the design, application, installation, operation and servicing of the applicable equipment. Read the manual carefully[...]
-
Page 5
Generac ® Pow er Systems, Inc. 3 2. 1 I NTRODUCTION T O I NS T ALL A TION This equipment has been wired and tested at the fac- tory . Installing the switch includes the following pro- cedures: • Mounting the enclosure. • Connecting power source and load leads. • Connecting the generator start circuit. • Installing/connecting any options an[...]
-
Page 6
4 Generac ® Pow er Systems, Inc. 2.4.1 2-POLE M E CHAN ISMS These switches (Figures 2.2 and 2.3) are used with a single phase system, when the single phase NEU- TRAL line is to be connected to a Neutral Lug and is not to be switched. Figure 2.2 — 100 Amp 2-pole T ransfer Mechanism Figure 2.3 — 200 Amp 2-pole T ransfer Mechanism 2.4.2 3-POLE M [...]
-
Page 7
Generac ® Pow er Systems, Inc. 5 Sectio n2—I n s t a l l a t i o n Generac “V” T ype and “Y” T ype T ransfer Switch 2.5 C ON N ECTING ST ART CIRCU IT W IRE S Control system interconnections (Figure 2.5) consist of UTILITY 1 and 2, LOAD 1 and 2; and leads 23 and 194. Control system interconnection leads must be run in a conduit that is se[...]
-
Page 8
6 Generac ® Pow er Systems, Inc. 3.1 F U NCTIONAL TE ST S AN D ADJ US TM ENTS F ollowing transfer switch installation and intercon- nection, inspect the entire installation carefully . A competent, qualified electrician should make the inspection. The installation should comply strictly with all appli- cable codes, standards, laws and regulations.[...]
-
Page 9
Generac ® Pow er Systems, Inc. 7 3.3.1 “Y” T YPE TR ANSF ER SWIT CH ES A manual handle was shipped with the transfer switch. T est manual operation for “Y ” type transfer switches as follows (Figure 3.2): 1. Check that the generator's Auto/Off/Manual switch has been set to OFF position. 2. Attach the square opening of the manual handl[...]
-
Page 10
8 Generac ® Pow er Systems, Inc. 3.5 GEN ER A T OR TES T S U N DER L O AD 1. Set the generator's main circuit breaker to its OFF or OPEN position. 2. Manually actuate the transfer switch main con- tacts to their ST ANDBY position. 3. T o start the generator , set the Auto/Off/Manual switch to MANU AL. When engine starts, let it sta- bilize fo[...]
-
Page 11
Generac ® Pow er Systems, Inc. 9 Sectio n4—N o t e s Generac “V” T ype and “Y” T ype T ransfer Switch[...]
-
Page 12
- O PEN S WIT C H T O TE S T - 2A @ 2 50 Vac MIN . SWITCH TYPE , SPS T ELECTRICAL RATINGS , U TILITY 1 U TILITY 2 1 94 C B 1 NE U TRA L CO NNE C TI O N N1 N2 T1 T2 T E1 E2 E NE U TRA L L UG TRAN S FE R S WIT CH U TILIT Y SU PPL Y L O A D CUS T O ME R 23 LO AD 2 U TILITY 2 U TILITY 1 A C G ENERAT OR CO NTR O L PANE L N O TE : P O WER LEAD S AND TRAN[...]
-
Page 13
S e c t i o n5—E l e c trical Schematics and Wiring Diagrams 200 Amp, 2-P ole T ransfer Switch - Drawing No. 0 7 4498-B Generac ® Pow er Systems, Inc. 11 E 1 T1 N1 E 2 T2 N2 B1 B2 A2 A1 T1 T2 B2 A2 B1 A1 T1 T2 6 9 TR 1 7 TR E1 E1 N2 N2 N1 N1 E2 205 1 2 6 23 19 4 23 19 4 N2 N1 NI N2 1 2 6 E2 T2 E1 L E G END L S1 , LS2 , LS3 - LIMIT SWITCHES , ACT[...]
-
Page 14
E1 T1 N1 E2 T2 N2 B1 B2 A2 A1 T1 T2 N3 T3 E3 N 3 N3 N3 N3 N3 N3 N3 B2 A2 B1 A1 T1 T2 6 9 TR 1 7 TR E1 E1 N2 N2 N1 N 1 E2 205 1 2 6 23 19 4 23 19 4 N2 N1 NI N2 1 2 6 E2 T2 T1 L E G END NO TE: A LL CO NTA C T S S H O WN WITH T RAN S FER S WIT C H IN U TILITY POS ITI O N. B A N2 E1 194 23 N 1 A N 2 T 2 T 1 N2 205 NI 205 E1 E1 E1 23 19 4 A 7 1 B 9 3 6 [...]
-
Page 15
S e c t i o n5—E l e c trical Schematics and Wiring Diagrams T ransfer Switch - Drawing No. 08 1 22 2-B Generac ® Pow er Systems, Inc. 13 NB N2A W IRIN G DIA G RAM T R - RELAY , TRANSFER T S - TERMINAL STRIP ( CUSTOMER CONNECTION ) N B - NE U TRAL BL OC K V R1 , VR2 - VARISTO R F 1 , F2 , F3 , F4-FUSE , 5A SENSING X A1 , XB1- LIMIT SWITCHES , AC[...]
-
Page 16
1 5 2 3 4 1 0 11 1 36 5 6 7 3 8 14 1 3 33 1 6 1 8 2 0 22 33 32 34 35 1 9 2 3 2 6 33 9 32 17 31 1 0 12 12 1 0 37 DE C A L DE C A L DE C A L DE C A L 42 21 39 38 4 0 41 4 3 2 4 2 5 44 Section 6 — Exploded Views and P arts Lists T ransfer Switch - Drawing No. 0 7 8589-H 14 Generac ® Pow er Systems, Inc.[...]
-
Page 17
Generac ® Pow er Systems, Inc. 15 ITEM P ART NO . QTY . DESCRIPTION 1 62642 1 SWITCH TRANSFER-#79953 62677 1 SWITCH TRANSFER-#79953-A 64198 1 SWITCH TRANSFER-#79953-B 2 C2267 4 M5-.8 x 12 SW A GEFORM HHC 3 49226 6 W ASHER, LOCK-M5 4 23897 4 W ASHER, FLA T -M5 5 57073 1 LUG, NEUTRAL 6 27628 1 NUT , HEX .375-16 7 22131 1 W ASHER, LOCK 3/8" 8 C2[...]
-
Page 18
16 Generac ® Pow er Systems, Inc. 20 1 3 8 REF. O NL Y TERM. S TRI P 2 8 21 6 5 3 1 9 2 3 1 6 1 22 17 4 1 8 14 2 5 1 5 1 6 7 12 11 9 2 6 24 34 47 10 11 12 31 32 30 33 35 22 2 3 1 6 21 36 T O RETAIN CO VE R ( BOTTOM POWER TERMINALS ) DE C A L A A DE C A L A A DE C A L 37 4 0 41 42 4 3 44 39 DE C A L DE C A L 4 5 4 9 4 8 4 6 ( POWER TERMINAL LUG ASS[...]
-
Page 19
Generac ® Pow er Systems, Inc. 17 ITEM P ART NO . QTY . DESCRIPTION 1 79849 1 ENCLOSURE 2* 74975 1 CO VER, ENCLOSURE 3 71340 1 SWITCH, TRANSFER 100A. 2-POLE 4 C2267 4 M5-.8 x 12 SW A GEFORM HHC 5 49226 4 M5 LOCK W ASHER 6 51713 4 M5 FLA T WASHER 7 63617 1 RELA Y , 12V . DC 10A. 8 27628 1 NUT , .375-16 9 C2265 2 M4-.7 x 12 SW A GEFORM PPH 10 A1661 [...]
-
Page 20
Part No. 078590 Revision D (05/29/02) Printed in U.S.A. Sectio n7—W a r r a n t y Generac “V” T ype and “Y” T ype T ransfer Switch GEN ERAC PO WER SY S TEMS ST AN D ARD T WO- YEAR LI M ITED W ARR ANT Y FOR GEN ERAC TRANSF ER SWIT CH SY STEMS NOTE: ALL UNITS MUST HA VE A ST ART -UP INSPECTION PERFORMED BY AN A UTHORIZED GENERAC DEALER. F o[...]