A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Giant P423, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Giant P423 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Giant P423. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Giant P423 should contain:
- informations concerning technical data of Giant P423
- name of the manufacturer and a year of construction of the Giant P423 item
- rules of operation, control and maintenance of the Giant P423 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Giant P423 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Giant P423, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Giant service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Giant P423.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Giant P423 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
P400 Series - 22 and 25mm V ersions Contents: Installation Instructions: page 2 Pump Specifications (except P425): pages 3-5 Exploded View: page 6 Parts List/Kits: page 7 Pump Specifications (P425): page 8 Repair Instructions/Torque Specs.: pages 9-10 Trouble Shooting Chart: page 11 Recommended Spare Parts List: page 11 Dimensions: back page Warran[...]
-
Page 2
2 INST ALLA TION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further reduce system pulsation. Dampeners can also reduce the severity of pres[...]
-
Page 3
3 NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil[...]
-
Page 4
4 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to ro[...]
-
Page 5
5 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to ro[...]
-
Page 6
6 EXPLODED VIEW - P420/P420-0011/P420-0021/ P422/ P423 AND P425 PUMPS[...]
-
Page 7
7 ITEM PART DESCRIPTION QTY. 1 08377 Crankcase 1 2 08378 Oil Fill Plug with Gasket 1 3 06479 Crankcase cover 1 3A 07186 Oil Sight Glass w/ Gasket 1 4 08380 O-Ring 1 5 07109 Oil Drain Plug 1 5A 07182 Gasket for Oil Drain Plug 1 5B 08092 Plug with Gasket 1 6 01010 Screw 4 6A 01011-0400 Spring Washer 4 7 05290 Bearing Cover Open 1 8 05291 Bearing Cove[...]
-
Page 8
8 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to ro[...]
-
Page 9
9 Repair Instructions P420/P420-0011/P420-0021/P422/P423 and P425 Note: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.e., the elastomers) from cutting and scoring. 1) With a socket wrench, remove the thre[...]
-
Page 10
10 Contact Giant Industries for service school information. Phone: (419) 531-4600 11) After installation of high pressure seals (23), place seal adaptor (20) with weep seals & pressure ring installed, weep return ring (25) and high pressure weep return ring (24) over plungers. Slide valve casing over plungers and seat firmly. Replace the 8 sock[...]
-
Page 11
11 PUMP SYSTEM MALFUNCTION MALFUNCTION CAUSE REMEDY The Pressure and/ Worn packing seals Replace packing seals or the Delivery Broken valve spring Replace spring Drops Belt slippage Tighten or Replace belt Worn or Damaged nozzle Replace nozzle Fouled discharge valve Clean valve assembly Fouled inlet strainer Clean strainer Worn or Damaged hose Repa[...]
-
Page 12
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-service car wash applications, the discharge manifolds will never fail, period. If they ever fail, we will replace them free of cha[...]