Go to page of
Similar user manuals
-
Heat Pump
Graco Model 260408
14 pages 0.56 mb -
Heat Pump
Graco 246428
10 pages 0.35 mb -
Heat Pump
Graco 239731
18 pages 1.83 mb -
Heat Pump
Graco 3A0096B
20 pages 1.71 mb -
Heat Pump
Graco 24V837
2 pages 0.75 mb -
Heat Pump
Graco 306518ZAC
16 pages 1.18 mb -
Heat Pump
Graco 24J399
18 pages 1.11 mb -
Heat Pump
Graco Series D
20 pages 0.34 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Graco 12 VDC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco 12 VDC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Graco 12 VDC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Graco 12 VDC should contain:
- informations concerning technical data of Graco 12 VDC
- name of the manufacturer and a year of construction of the Graco 12 VDC item
- rules of operation, control and maintenance of the Graco 12 VDC item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco 12 VDC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco 12 VDC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco 12 VDC.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco 12 VDC item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
311304H Instructions - Parts List GTP10 Pump For pumping gasoline, diesel fu el, and kerosene. Do not use to pump other fluids including water. Models 260000 through 260017, 260019, 260024, 260580, and 260581 10 gpm (38 lpm), 12 VDC (C SA C/US listed motor) Models 260020 an d 260021, 10 gpm (38 lpm), 24 VDC Models 260022 and 260023, 12 gpm (45 lpm)[...]
-
Page 2
Models 2 311304H Models Part No. Hose Nozzle 12 VDC, 10 gpm (38 lpm), 12.5 amps 260000 260069 - 12 ft (3.66 m) grounded 260079 - manual, leaded/die sel 260001 260069 - 12 ft (3.66 m) grounded 260082 - automatic, regula r/diesel 260002 260069 - 12 ft (3.66 m) ground ed 260078 - manual, unleaded 260003 260069 - 12 ft (3.66 m) grounded 260083 - automa[...]
-
Page 3
Models 311304H 3[...]
-
Page 4
Warnings 4 311304H Warnings The following general warn ings are for the setup, use, ground ing, maintenance, and repair of this equipme nt. Addi- tional, more specific warnings may be found th ro ughout the body of this manual where applicable. Symbols appea r- ing in the body of the manual re fer to these general warnin gs. When these symbols appe[...]
-
Page 5
Warnings 311304H 5 EQUIPMENT MISUSE HAZARD Misuse can cause de ath or serious injury. • Do not operate the unit when fatigued or under the influen ce of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equip ment manuals. • Use fluids and solve[...]
-
Page 6
Installation 6 311304H Installation When unpacking pump, check for shipp ing damage. Report any shipping damage to delivering carrier imme- diately. Mounting Pump 1. Apply PTFE thread tape (provided with the pump) to large thread of bu ng adapter (9) (2 in. X 1 ½ in. reducer fitting). Install bung ad apter to fuel tank. 2. Assemble s uction tube s[...]
-
Page 7
Installation 311304H 7 3. Cut the suction tube so that it is 2 in. (55 mm) from the bottom of the tank when installed in the tank. 4. Insert ga sket (7f) into union nut (1k). If using Grac o supplied PVC suction tube it is not necess ary to apply thread tape before assembly, just scre w into pump inlet (1j). If using me tal suction tube (not sup- p[...]
-
Page 8
Installation 8 311304H Electrical Installation 12 VDC and 24 VDC To install wiring for a ne gative grou nd system : 1. Ensure pump switch is OFF. 2. To remove electrical cover (2a) , remove four bolts (2c). 3. Strip 3 in. (76 mm ) of outside insu lation from power cable (6c) from e nd opposite of fuse. 4. Strip 3/8 in. (10 mm) of in sulation from r[...]
-
Page 9
Operation 311304H 9 Priming Pump All pump models should prime with in 5 seconds after pump is turned on up to a height of 36 in. (9 1 mm). Pumps installed at height up to 5 ft. (1.52 m) may have difficulty priming. Follow pr ocedure below to initiate prime. Pumps installed at suction height above 5 ft. (1.52 m) will have difficulty in holding prime[...]
-
Page 10
Troubleshooting 10 311304H Troubleshooting Problem Cause Solution Motor runs but pump will not prime. Motor rotation wrong. (12 VDC and 24 VDC units only.) Check wiring in structions for possible problems. Missing relief valve o-ri ng seal (4c/7a). Remove gear cover (1b) inspect seal (4c/7a), replace if missing or damaged. Sheared drive key (1f/7 c[...]
-
Page 11
Troubleshooti ng 311304H 11 Motor stalls when nozzle is clos ed. Bypass relief valve (4a) stuck. Inspect relief valve, making sure poppet is free. Replace if damaged. Low supply voltage. Check supply voltage. Gears (1c/10a) dam aged and binding. Inspect gears. Gears sh ould turn freely. Replace if damage d. Faulty motor. Replace motor. Fuel leaking[...]
-
Page 12
Parts Drawing 12 311304H Parts Drawing 3a 3c 3d/7e 1a 8e 8b 8f 8g 1h 1e/7b/10c 1f/7c/10b 2e 2f 3b 1b 1c/ 10a 1d 4b 4a 2h 2i 8c 8a 8d 4c/ 9 7f 1k 1g/7d 2g 2c 2b 2d 5c 5a 2a 2c 6b 6c 6a Models 260000 through 260017, 260019, 260024, 260580, and 260581, 12 VDC Models 260020 and 260021, 24 VDC Models 260022 and 260023, 230 VAC Models 260025 through 2600[...]
-
Page 13
Parts Li st 311304H 13 Parts List Models 260000 through 260017, 260019, 260024, 260580, and 260581, 12 VDC Models 260020 and 260021, 24 VDC Models 260022 and 260023, 230 VAC Models 260025 through 260028, 115 VAC Ref. No. Description Qty . 1 260458 KIT, pump with swivel, blue (includes items 1a -1k) 260459 KIT, pump without swivel, blue (includes it[...]
-
Page 14
Parts List (continued) 14 311304H Parts List (continued) Models 260000 through 260017, 260019, and 260024, 12 VDC Models 260020 and 260021, 24 VDC Models 260022 and 260023, 230 VAC Models 260025 through 260028, 115 VAC Replacement Danger an d Warning labels, tags, and cards are available at no cost. * Not used on models 260004, 2 60006, 260008,[...]
-
Page 15
Technical Data 311304H 15 Technical Data Valox ® is a register ed trademar k of the General Elect ric Company Performance Chart Working pressure 10 psi (0.07 MPa, 0.7 bar) Inlet size 1 in. npt Outlet siz e 3/4 in. npt Weight 20 lb (9 kg) Power cable 18 ft (5.5 m), 14 AWG (12 VDC an d 24 VDC models only) Current draw 12 VDC models: 12.5 amps 24 VDC[...]
-
Page 16
All written and visual data contained in this document reflects the latest product info r mation available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. This manual contains English. MM 311304 Graco Headquarters: Minne apolis International Offices: Belgium, China, Japan, Korea GRACO INC. P.O. BOX[...]