Go to page of
Similar user manuals
-
Water Pump
Ingersoll-Rand PD15P-X
8 pages 0.99 mb -
Water Pump
Ingersoll-Rand 650736-15X
1 pages 0.07 mb -
Water Pump
Ingersoll-Rand 650941-X-C
2 pages 0.1 mb -
Water Pump
Ingersoll-Rand 650632-X-C
2 pages 0.14 mb -
Water Pump
Ingersoll-Rand CHOP-CHECK 650941-X-C
2 pages 0.16 mb -
Water Pump
Ingersoll-Rand PD03P-XXX-XXX
12 pages 0.74 mb -
Water Pump
Ingersoll-Rand 662605
4 pages 1.36 mb -
Water Pump
Ingersoll-Rand PM10X-X-X-A02
8 pages 0.95 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Ingersoll-Rand 6661AX-X-C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ingersoll-Rand 6661AX-X-C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Ingersoll-Rand 6661AX-X-C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Ingersoll-Rand 6661AX-X-C should contain:
- informations concerning technical data of Ingersoll-Rand 6661AX-X-C
- name of the manufacturer and a year of construction of the Ingersoll-Rand 6661AX-X-C item
- rules of operation, control and maintenance of the Ingersoll-Rand 6661AX-X-C item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ingersoll-Rand 6661AX-X-C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ingersoll-Rand 6661AX-X-C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ingersoll-Rand service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ingersoll-Rand 6661AX-X-C.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Ingersoll-Rand 6661AX-X-C item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
E 2010 )$; INGERSOLL RAND COMP ANY 209 NORTH MAIN STREET - - BRY AN, OHIO 43506 OPERA T OR’S MANUAL 6661AX - X - C RELEASED: 9-1 1-89 REVISED: (REV . INCLUDING: OPERA TION, INST ALLA TION & MAINTENANCE 1” DIAPHRAGM PUMP 1:1 RA TIO (NON - MET [...]
-
Page 2
6661AX-X-C P A G E 2O F8 OPERA TING AND SAFETY PRECAUTIONS READ, UNDERST AND AND FOLLOW THIS INFORMA TION TO A VOID INJURY AND PROPERTY DAMAGE. EXCESSIVE AIR PRESSURE ST A TIC SPARK HAZARDOUS MA TERIALS HAZARDOUS PRESSURE W ARNING EXCESSIVE AIR PRESSURE. Can cause pump damage, personal injury or property damage. S Be sure material hoses and other c[...]
-
Page 3
P A G E 3O F8 6661AX-X-C AIR AND LUBE REQUIREMENTS W ARNING EXCESSIVE AIR PRESSURE. Can cause pump damage, personal injury or property damage. S A filter capable of filtering out particles larger than 50 microns should be used on the air supply . There is no lubrication required other than the “O” ring lubricant which is applied during assembly[...]
-
Page 4
MA TERIAL CODE [B] = Nitrile [C] = Carbon Steel [E] = E.P .R. [H] = Hytrel [K] = P .V .D.F . (Kynar) [N] = Neoprene [P] = Polypropylene [SP] = Santoprene [SPM] = Medical Grade Santoprene [SH] = Hard Stainless Steel [SS] = Stainless Steel [T] = PTFE [U] = Polyurethane [V] = Viton V “Smart Parts” keep these items on hand in addition to the Se rvi[...]
-
Page 5
2 k 3 k 4 k 6 , 7 15 28 21 22 25 , 26 , 36 37 21 22 FOR THE AIR MOTOR SECTION SEE P AGES 6 & 7 19 k 33 k 5 1 24 19 k 35 27 , 38 , 34 7 VIEW FOR -XX4 (PTFE DIAPHRAGM) CONFIGURA TION ONL Y AIR SIDE SANTOPRENE (GREEN when used as backer) FLUID SIDE PTFE (WHITE) . TORQUE REQUIREMENTS , LUBRICA TION / SEALANTS NOTE: DO NOT OVERTIGHTEN F ASTENERS 33 [...]
-
Page 6
6661AX-X-C P A G E 6O F8 P ARTS LIST / 6661AX -X-C AIR MOT OR SECTION n Indicates parts included in 6371 18-C Air Section Service Kit. SERVICE KIT NOTE: Service Kit 6371 18 -C is a general repair kit for all 1” and larger ARO diaphragm pump air motors. It contains extra “O” Rings and extra parts that may not be needed to service this model. I[...]
-
Page 7
P A G E 7O F8 6661AX-X-C P ARTS LIST / 6661AX -X-C AIR SECTION MAJOR V AL VE See cross section detail Figure 5. PILOT V AL VE 101 11 8 k 111 11 2 k 11 3 k 11 4 11 5 11 6 11 7 11 9 k 102 k 103 k 104 123 z 121 122 k 120 107 108 109 11 0 k . 105 IMPORT ANT BE CERT AIN TO ORIENT (115) SP ACER LEGS A W A Y FROM BLOCKING INTERNAL PORTS WHEN REASSEMBLING [...]
-
Page 8
PN 97999-20 6661AX-X-C P A G E 8O F8 TROUBLE SHOOTING Product discharged from exhaust outlet. S Check for diaphragm rupture. S Check tightness of diaphragm nut. Air bubbles in product discharge. S Check connections of suction plumbing. S Check “O” rings between intake manifold and fluid caps. S Check tightness of diaphragm nut. Low output volum[...]