Lincoln 1132-080-A manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Lincoln 1132-080-A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lincoln 1132-080-A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Lincoln 1132-080-A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Lincoln 1132-080-A should contain:
- informations concerning technical data of Lincoln 1132-080-A
- name of the manufacturer and a year of construction of the Lincoln 1132-080-A item
- rules of operation, control and maintenance of the Lincoln 1132-080-A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lincoln 1132-080-A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lincoln 1132-080-A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lincoln service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lincoln 1132-080-A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Lincoln 1132-080-A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Imp2DigAdvServ REV 3/20/08 SERVICE MANUAL (DOMESTIC) IMPINGER CONVEYOR OVENS MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1, 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1132-080-A1, 1130-08H-A, 1131-08H-A, 1132-08H-A, 1133-08H-A, 1161-080-A, 1162-080-A WITH PUSH BUTTON CONTROLS Lincoln Foodservice [...]

  • Page 2

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 2 SEQUENCE OF OPERATION IMPINGER II ADVANTAGE, GAS (OVENS WITH PUSH BUTTON CONTROLS) MODEL 1116-080-A NAT. GAS 120VAC 60 HZ. 1 PHASE MODEL 1116-080-A1 NAT. GAS 120VAC 60 HZ. 1 PHASE MODEL 1117-080-A LP GAS 120VAC 60 HZ. 1 PHASE MODEL 1117-080-A1 LP GAS 120VAC 60 HZ. 1 PHASE POWER[...]

  • Page 3

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 3 SEQUENCE OF OPERATION IMPINGER II ADVANTAGE, ELECTRIC (OVENS WITH PUSH BUTTON CONTROLS) 1130-080-A 120/208VAC 60 HZ. 1 PHASE 1130-080-A1 120/208VAC 60 HZ. 1 PHASE 1130-08H-A 208 VAC 60 HZ. 1 PHASE 1131-080-A 120/240VAC 60 HZ. 1 PHASE 1131-080-A1 120/240VAC 60 HZ. 1 PHASE 1131-0[...]

  • Page 4

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 4 SCHEMATIC DIAGRAM MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1[...]

  • Page 5

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 5 SCHEMATIC DIAGRAM MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1 SCHEMATIC DIAGRAM[...]

  • Page 6

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 6 MODEL 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1[...]

  • Page 7

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 7 SCHEMATIC DIAGRAM MODEL 1161-080-A[...]

  • Page 8

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 8 SCHEMATIC DIAGRAM MODEL 1162-080-A[...]

  • Page 9

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 9 SCHEMATIC DIAGRAM MODEL 1130-08H-A, 1131-08H-A[...]

  • Page 10

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 10 SCHEMATIC DIAGRAM MODEL 1132-08H-A, 1133-08H-A[...]

  • Page 11

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 11 TROUBLESHOOTING GUIDE GAS OVENS MODEL 1116-080-A NAT. GAS 120VAC 60 HZ. MODEL 1116-080-A1 NAT. GAS 120VAC 60 HZ. MODEL 1117-080-A LP GAS 120VAC 60 HZ. MODEL 1117-080-A1 LP GAS 120VAC 60 HZ. SYMPTOM POSSIBLE CAUSE EVALUATION Oven fan will not run Incoming power supply Check cir[...]

  • Page 12

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 12 the main fan motor) to neutral. If no voltage is present, trace wiring back to the main power switch. If voltage is present, check for 120VAC at wire #22 (output of centrifugal switch) to neutral. If no voltage is present at #22, and the motor is runni ng, repla ce the main fa[...]

  • Page 13

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 13 occur. If flame is not detected, the ignition control will shut off and lock out. To reset the ignition control, turn off the power switch for 45 seconds, then turn the switch on to re-try ignition. The igniti on control requires a minimum of 0.8 DC mi croamp s to prove flame.[...]

  • Page 14

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 14 Oven control If the thermoc ouple checks good, but the oven control display indicates that there is a therm ocouple failure, replace the oven control. If the oven control indicates a temperature reading but the oven wo n’t heat, proceed. Thermocouple WITH POWER ON AND T HERM[...]

  • Page 15

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 15 needed. WARNING: Capacitor ha s a stored charge, discharge before testing. Switch, conveyor reversing Check continuity between swit ch terminals. Replace switch as needed. Oven control If there is 120VAC supplied to the motor, and the motor, capacitor, and reversing switch che[...]

  • Page 16

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 16 1130-080-A 120/208VAC 60 HZ. 1 PHASE 1130-080-A1 120/208VAC 60 HZ. 1 PHASE 1130-08H-A 208 VAC 60 HZ. 1 PHASE 1131-080-A 120/240VAC 60 HZ. 1 PHASE 1131-080-A1 120/240VAC 60 HZ. 1 PHASE 1131-08H-A 240 VAC 60 HZ. 1 PHASE 1132-080-A 120/208VAC 60 HZ. 3 PHASE 1132-080-A1 120/208VAC[...]

  • Page 17

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 17 Replace relay as needed. Main fan runs after 20 minute cool down Oven start relay Contacts should open whe n main power switch is turned off. Replace relay as needed. 20 Minute time delay 120VAC at terminal # 2 sh ould discontinue approx. 20 minutes after main power is switche[...]

  • Page 18

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 18 If there is a read-out on the control, set the co ntrol to maximum temperature (see installation operations manual for temperature adju stment). With the control set at maximum temperature, check for supply voltage at mercury contactor. If there is voltage at the mercury conta[...]

  • Page 19

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 19 thermal protection and w ill cease to operate if overheating occurs. As the motor overheats and then cools, this will cause the oven to cycle on a nd off intermittently. Improper ventilation or lack of preventive maintenance may cause this. Also, most of the problems listed un[...]

  • Page 20

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 20 Conveyor motor If there is voltage supplied to the hall effect sensor, check for a frequency output fro m the hall effect sensor. Measure frequen cy across the yellow and white wires at the motor connecto r. Frequency reading sho uld be approx. 25 – 100 Hz. If these readings[...]

  • Page 21

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 21 CAPACITOR – REPLACEMENT A. Shut off power at main breaker. B. Remove rear control box cover. C. Discharge capacitor. D. Remove capacitor. E. Reassemble in reverse order and check system operation. ON/OFF SWITCH – REPLACEMENT A. Shut off power at main breaker. B. Remove con[...]

  • Page 22

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 22 F. Reassemble in reverse ord er and check system oper ation. Be sure capill ary tube is securely in the mount. NOTE: Push reset butt on on new thermostat. TRANSFORMER, BURNER – REPLACEMENT A. Shut off power at main breaker. B. Remove conveyor and front control box cover. C. [...]

  • Page 23

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 23 BURNER CONTROL – REPLACEMENT A. Shut off power at main breaker. B. Remove conveyor and front control box cover. C. Remove wires from control and mark for reassembly. D. Remove mounting screws from control and rem ove burner control. E. Reassemble in reverse order and check s[...]

  • Page 24

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 24 BYPASS ORIFICE – REPLACEMENT A. Shut off power at main breaker. B. Shut off gas supply to the oven and di sconnect the flexible gas line to oven. C. Remove rear control box cover. D. Disconnect bypass tube from gas valve. E. Remove bypass orifice from gas valve. F. Reassembl[...]

  • Page 25

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 25 G. Turn adjusting screw on ai r pressure switch fully counter clockwi se. H. Turn oven “on”. I. Turn adjusting screw on air pressure switch clockwise until heat shuts off. J. Turn adjusting scre w on ai r pressu re switch counter clockwise ¼ tu rn. K. Reassemble control p[...]

  • Page 26

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 26 GENERAL VIEW IMPINGER II ADVANTAGE MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1, 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1132-080-A1, 1130-08H-A, 1131-08H-A, 1132-08H-A, 1133-08H-A, 1161-080-A, 1162-080-A LETTER PART NUM[...]

  • Page 27

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 27 GENERAL VIEW[...]

  • Page 28

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 28 CONTROL BOX, FRONT MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1 LETTER PART NUMBER DESCRIPTION A 369805 Switch, on/off B 370408 Facia, pushbutton C 370417 Control board 370409 Display (digital only) D 369531 Transformer, 24VAC E 369507 Thermostat, cooling fan F 36912[...]

  • Page 29

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 29 CONTROL BOX, FRONT VIEW MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1[...]

  • Page 30

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 30 CONTROL BOX, FRONT MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1, 1130-08H-A, 1131-08H-A, 1132-08H-A, 1133-08H-A, 1161-080-A, 1162-080-A LETTER PART NUMBER DESCRIPTION A 369680 Front cover assy. B 369508 Timer, 20 minu[...]

  • Page 31

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 31 CONTROL BOX, FRONT VIEW MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1, 1130-08H-A, 1131-08H-A, 1132-08H-A, 1133-08H-A, 1161-080-A, 1162-080-A[...]

  • Page 32

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 32 CONTROL BOX, REAR MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1 LETTER PART NUMBER DESCRIPTION A 369192 Capacitor B 370378 Conveyor motor assy. (S/N 2052462 & Below) 370675 Conveyor motor as sy. (S/N 2052463 & Above) C 369901 Burner manifold D 369568 Burner ve[...]

  • Page 33

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 33 CONTROL BOX, REAR VIEW MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1[...]

  • Page 34

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 34 CONTROL BOX REAR MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1, 1130-08H-A, 1131-08H-A, 1132-08H-A, 1133-08H-A, 1161-080-A, 1162-080-A LETTER PART NUMBER DESCRIPTION A 369192 Capacitor B 369200 Relay, main fan C 369124[...]

  • Page 35

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 35 CONTROL BOX, REAR VIEW MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1, 1130-08H-A, 1131-08H-A, 1132-08H-A, 1133-08H-A, 1161-080-A, 1162-080-A[...]

  • Page 36

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 36 OVEN BACK ASSEMBLY LETTER PART NUMBER DESCRIPTION A 369182 Fan B 369899 Fan shroud C 369655 Stand off D Heating element 369183 208 Volt 369184 240 Volt 370648 208 Volt – Models 1130-08H-A & 1132-08H-A (S/N 10062053640 & below) 370645 240 Volt – Models 1131-08H-A &a[...]

  • Page 37

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 37 OVEN BACK ASSEMBLY VIEW[...]

  • Page 38

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 38 CONVEYOR / DOOR LETTER PART NUMBER DESCRIPTION A 369190 Coupler (S/N 2052462 & below) 370671 Coupler (S/N 2052463 & above) B 369512 Coupling center (S/N 2052462 & below) C 369269 Ball plunger (S/N 2052462 & below) D 370116 Set screw (S/N 2052462 & below) E [...]

  • Page 39

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 39 CONVEYOR / DOOR VIEW[...]

  • Page 40

    Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 40[...]