Go to page of
Similar user manuals
-
Power Supply
MGE UPS Systems 800 Tower
36 pages 0.66 mb -
Power Supply
MGE UPS Systems EXB RT 3U
24 pages 0.67 mb -
Power Supply
MGE UPS Systems ESV 8+Rack
24 pages 0.34 mb -
Power Supply
MGE UPS Systems GES-801L
22 pages 0.11 mb -
Power Supply
MGE UPS Systems 3.5 to 21 kVA N+1
54 pages 0.76 mb -
Power Supply
MGE UPS Systems 3
34 pages 1.7 mb -
Power Supply
MGE UPS Systems S EXB 2500
22 pages 1.45 mb -
Power Supply
MGE UPS Systems 6000
20 pages 0.17 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of MGE UPS Systems S 3000 RT 3U, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of MGE UPS Systems S 3000 RT 3U one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of MGE UPS Systems S 3000 RT 3U. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of MGE UPS Systems S 3000 RT 3U should contain:
- informations concerning technical data of MGE UPS Systems S 3000 RT 3U
- name of the manufacturer and a year of construction of the MGE UPS Systems S 3000 RT 3U item
- rules of operation, control and maintenance of the MGE UPS Systems S 3000 RT 3U item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of MGE UPS Systems S 3000 RT 3U alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of MGE UPS Systems S 3000 RT 3U, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the MGE UPS Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of MGE UPS Systems S 3000 RT 3U.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the MGE UPS Systems S 3000 RT 3U item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
34003641FR/ AA - Page 1 T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R www.mgeups.com Installation and user manual Evolution S 1250 RT 2U S 1750 RT 2U 2000 RT 2U S 2500 RT 2U S 3000 RT 2U S 3000 RT 3U S EXB 1250/1750 RT 2U S EXB 2500/3000 RT 2U S EXB 2500/3000 RT 3U[...]
-
Page 2
34008236EN /AA - Page 2[...]
-
Page 3
34008236E N/AA - Page 3 Introduction Environmental protection MGE UPS SYSTEMS has implemented an environmental-protection policy. Products are developed accordi ng to an eco-design approach. Subst ances This product does not contain CFCs, HCFCs or asbestos. Packing To improve waste treatment and facilitate re cycling, separate the various packing c[...]
-
Page 4
34008236EN /AA - Page 4 Introduction Pictograms Important instructions that must always be followed. Information, advice, help. Visual indication. Action. Audio signal. In the illustrations on the follow ing pages, the symbols below are used: LED off LED on LED flashing[...]
-
Page 5
34008236E N/AA - Page 5 Contents 1. Present ation 1.1 St andard positions ..... .............. .............. ................ .............. .............. ............... .............. ............ 6 T ower position ............ .............. .............. ................. .............. .............. .............. .............. ..........[...]
-
Page 6
34008236EN /AA - Page 6 1. Presentation 1.1 Standard positions Tower position Rack position Dimensions (W x H x D ) in mm S 1250 RT 2U S 1750 RT 2U 2000 RT 2U 440 x 86 x 509 S 2500 RT 2U S 3000 RT 2U 440 x 86 x 634 S 3000 RT 3U 440 x 131 x 484 S EXB 1250/17 50 RT 2U 440 x 86 x 509 S EXB 2500/30 00 RT 2U 440 x 86 x 634 S EXB 2500/30 00 RT 3U 440 x 1[...]
-
Page 7
34008236E N/AA - Page 7 1. Presentation 1.2 Rear panels Evolution S 2500 / S 3000 Evolution S EXB (optional battery module) 1.3 Control panel (1) USB co mmunicat ion por t (2) RS232 communication port (3) Connector for automatic recognition of an additional battery module (4) Slot for optional communication card (5) Connector for ROO (remote ON/OFF[...]
-
Page 8
34008236EN /AA - Page 8 2. Installation 2.1 Unpacking and contents check (30) Evolution UPS (31) connection cable to AC-power source ( Evolution S 2500 and S 3000 models only) (32) 2 connection cables fo r the protected equipment (33) RS232 communication cable (34) USB communication cable (35) 2 systems to secure power plugs (36)Solution-Pac CD-ROM[...]
-
Page 9
34008236E N/AA - Page 9 2. Installation 2.2 Installation in tower position 2.3 Installation in rack position It is advised to first install the battery module , then the power module above . Note. The two su pports for the upright posit ion are used on the RT 2U version only. Follow steps 1 to 4 for module mounting on the rails. The rails and neces[...]
-
Page 10
34008236EN /AA - Page 10 2. Installation 2.4 Communication ports Connection of RS232 or USB communication port (optional) Installation of the communication cards (optional, standard on the Netpack versions ) Characteristics of the contact communication port (optional) The RS232 and USB commun ication ports cannot operate simultan eously. 1 - Connec[...]
-
Page 11
34008236EN /AA - Page 11 2. Installation 2.5 Connection with a FlexPDU (Power Distribution Unit) module (optional) 2.6 Connection with a HotSwap MBP module (optional) The HotSwap MBP module makes it possible to serv ice or even replace the UPS wit hout affecting the connected loads ( HotSwap function). 1 - Evolution S 2500 / S 3000 : connect the UP[...]
-
Page 12
34008236EN /AA - Page 12 2. Installation HotSwap MBP module operation UPS st art-up with th e HotSwap MBP module 1 - Check that the UPS is correctly connected to the Hot Swap MBP module. 2 - Set switch (53) to Normal position. 3 - Start the UPS by pressing the ON/OFF button (24) on the UPS control panel. The load is supplied by the UPS. LED (51) &q[...]
-
Page 13
34008236EN /AA - Page 13 3. Operation 3.1 Start-up and norm al operation 3.2 Operation on battery power T ransfer to battery power Low-battery warning Press button (24) for approximately 1 second. ◗ The buzzer beeps once and all the LEDs go ON simultaneously. ◗ If AC input power is available, button (24) and LED (25) are ON. The load is supplie[...]
-
Page 14
34008236EN /AA - Page 14 3. Operation End of battery backup time 3.3 Return of AC input power Following an outage, the UPS restarts aut omatically when AC input power returns (un less the restart function has been disabled via UPS personalisation) and the load is again su pplied. 3.4 UPS shutdown 3.5 UPS remote control functions Evolution offers a [...]
-
Page 15
34008236EN /AA - Page 15 3. Operation Contact open: UPS shutdown Contact closed: UPS start-up (UPS connected to AC power and AC power is available) Note. The local ON/OFF control using button (24) ove rrides the remote-control function. Contact open: UPS shutdown, LED (26) goes ON To return to normal operation, deactivate the remote external contac[...]
-
Page 16
34008236EN /AA - Page 16 4. Personalisation using external software Main-outpu t personalisatio n V olt age-threshold personalisation (1) Low threshold for transfer to battery is 1 50 V. UPS-sensitivity personalisation UPS ON/OFF personalisation Battery personal isation ◗ Insert the Solution-Pac CD-ROM in the drive. ◗ On the first navigation sc[...]
-
Page 17
34008236EN /AA - Page 17 5. Maintenance 5.1 Troubleshooting Troubleshooting a UPS equipped with the HotSwap MBP module Indication Diag nostic Correction 1 When the UPS is started using button (24) , all the LEDs go ON once and the buzzer beeps once, then LED (26) remains ON. The remote power off (RPO) contact has been act ivated to shut down the UP[...]
-
Page 18
34008236EN /AA - Page 18 5. Maintenance 5.2 Battery-module replacement Safety recommendations The battery can cause electrocutio n and high short-circuit currents. The follo wing safety precaution s are required before servicing the battery components: ◗ Remove watches, rings, bracelets and all othe r metal objects from the hands and arms, ◗ Us[...]
-
Page 19
34008236EN /AA - Page 19 5. Maintenance Mounting the new battery module Carry out the above instructions in reverse order. 5.3 Maintenance on a UPS equipp ed with the HotSwap MBP module 5.4 Training centre ◗ To ensure safety and high performance, use only batteries supplied by MGE UPS SYSTEMS. ◗ Take care to firmly press together th e two parts[...]
-
Page 20
34008236EN /AA - Page 20 6. Appendices 6.1 Technical specifications (1) The high and low threshol ds can be adjusted using Pers onal Solution-Pac software. (2) Up to 40 Hz in low-sensitivity mode (programmable using Personal Solution-Pac software. (3) Adjustable to 200 V (10% derating of output power) / 208 V / 220 V / 230 V / 240 V. (4) Battery Ev[...]
-
Page 21
34008236EN /AA - Page 21 6. Appendices 6.2 Glossary Backup time T ime during which t he load can be supplied by the UPS operating on battery power . Battery test Internal UPS test to check battery status. Booster mode Automatic UPS mode that steps up the AC voltage if it is too low, to a level above the personalised set-poi nt, without discharging [...]
-
Page 22
34008236EN /AA MGE UPS SYSTEMS T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R 140, Avenue Jean Kuntzmann ZIRST - M ontbonno t St Martin 38334 - Saint Ismier Cedex - Fr ance www.mgeups.com[...]