Go to page of
Similar user manuals
-
Indoor Fireplace
Napoleon Fireplaces BGD36NTR
32 pages 1.14 mb -
Indoor Fireplace
Napoleon Fireplaces GVFS60-P
16 pages 0.31 mb -
Indoor Fireplace
Napoleon Fireplaces GDS26P
32 pages 4.21 mb -
Indoor Fireplace
Napoleon Fireplaces BGD36CFNTR
48 pages 6.09 mb -
Indoor Fireplace
Napoleon Fireplaces EF30G
20 pages 2.19 mb -
Indoor Fireplace
Napoleon Fireplaces GT8N
16 pages 1.51 mb -
Indoor Fireplace
Napoleon Fireplaces GD45-N
24 pages 0.68 mb -
Indoor Fireplace
Napoleon Fireplaces EPA1100
20 pages 1.08 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Napoleon Fireplaces BGD40-P, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Napoleon Fireplaces BGD40-P one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Napoleon Fireplaces BGD40-P. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Napoleon Fireplaces BGD40-P should contain:
- informations concerning technical data of Napoleon Fireplaces BGD40-P
- name of the manufacturer and a year of construction of the Napoleon Fireplaces BGD40-P item
- rules of operation, control and maintenance of the Napoleon Fireplaces BGD40-P item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Napoleon Fireplaces BGD40-P alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Napoleon Fireplaces BGD40-P, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Napoleon Fireplaces service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Napoleon Fireplaces BGD40-P.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Napoleon Fireplaces BGD40-P item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 W415-0299 / J / 04.14.08 W415-0299 / J / 04.14.08 $10.00[...]
-
Page 2
2 W415-0299 / J / 04.14.08 Pg 3-5 INTRODUCTION W arranty General Instructions General Information Care of Glass & Plated Parts Dimensions 6-13 VENTING V ent Lengths Minimum Air T erminal Location Clearances V enting Application Flow Chart T ypical Minimum and Maximum V ent Lengths Special V ent Installation V enting Options 14-15 PENINSULA INST[...]
-
Page 3
3 W415-0299 / J / 04.14.08 NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test[...]
-
Page 4
4 W415-0299 / J / 04.14.08 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Installa- tion practices vary from region to region and it is important to know the specifi cs that apply to your area, For example: in Massachusetts State: • The fi replace damper must be removed or welded in t[...]
-
Page 5
5 W415-0299 / J / 04.14.08 DIMENSIONS SEE-THRU PENINSULA OPEN-END FIGURE 1a FIGURE 1b FIGURE 1c[...]
-
Page 6
6 W415-0299 / J / 04.14.08 Use only Wolf Steel or Simpson Dura-V ent Model DV -GS, Selkirk Direct T emp or American Metal Amerivent venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal loca- tions for either system are set out in this manual and must be adhered to. For Simpson Dura-V[...]
-
Page 7
7 W415-0299 / J / 04.14.08 MINIMUM AIR TERMINAL L OCA TION CLEARANCES FIGURE 2[...]
-
Page 8
8 W415-0299 / J / 04.14.08 VENTING APPLICA TION FL O W CHART VER TICAL TERMINA TION HORIZONT AL TERMINA TION V ertical rise is equal to or great- er than the horizontal run Horizontal run + v er ti- cal rise to maximum of 40 feet V ertical rise is equal to or great- er than the horizontal run Horizontal run + v er ti- cal rise to maximum of 40 feet[...]
-
Page 9
9 W415-0299 / J / 04.14.08 Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum of 12" above grade. When venting, the horizontal run must be kept to a maximum of 20 feet. If a 20 foot horizontal run is required,[...]
-
Page 10
10 W415-0299 / J / 04.14.08 REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 When (H T ) < (V T ) Simple venting confi guration (only one 45º and 90° elbow) for the following symbols used in the venting calculations and examples are: > - greater than >[...]
-
Page 11
11 W415-0299 / J / 04.14.08 See graph to determine the required vertical rise V T for the required hori- zontal run H T . For vent confi gurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2: H T + V T < 24.75 feet FIGURE 7 REQUIRED VERTICAL RISE IN INCHES (V T ) HORIZONT AL VE[...]
-
Page 12
12 W415-0299 / J / 04.14.08 Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T = 10.9 + 15 = 25.9 ft Formula 1: H T < V T 10.9 < 15 Formula [...]
-
Page 13
13 W415-0299 / J / 04.14.08 For vent confi gurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2: H T + V T < 40 feet Example 4: When (H T ) > (V T ) Simple venting confi gurations See graph to determine the required vertical rise V T for the required horizontal run [...]
-
Page 14
14 W415-0299 / J / 04.14.08 Refer to pages 6-13. All venting must have a minimum clear- ance of 2" to combustible material on the top and 1" to the sides and bottom. See Page 18 for additional framing dimensions. NOTE: In order to avoid the possibility of exposed insula- tion or vapor barrier coming in contact with the fi replace body , [...]
-
Page 15
15 W415-0299 / J / 04.14.08 Combustible materials may be installed fl ush with the front of the fi replace but must not cover any of the black face-areas of the fi replace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas. It is not necessary to install a hearth extension with this fi replace system. When roug[...]
-
Page 16
16 W415-0299 / J / 04.14.08 Refer to pages 6-13. All venting must have a minimum clear- ance of 2" to combustible material on the top and 1" on the sides and bottom. See Page 18 for additional framing dimensions. NOTE: In order to avoid the possibility of exposed insula- tion or vapor barrier coming in contact with the fi replace body , [...]
-
Page 17
17 W415-0299 / J / 04.14.08 Refer to pages 6-13. All venting must have a minimum clear- ance of 2" to combustible material on the top and 1" to the sides and bottom. See Page 18 for additional framing dimensions. NOTE: In order to avoid the possibility of exposed insula- tion or vapor barrier coming in contact with the fi replace body , [...]
-
Page 18
18 W415-0299 / J / 04.14.08 There must be a minimum of 2" clearance to combustible ma- terial on the top and 2" to the sides and bottom when framing around all venting options. See pages 10-13. FIGURE 27a FIGURE 27b Horizontal V ent Off Fireplace V ertical Vent Of f Fireplace A = 43" using fl exible vent components. B = 45" usi[...]
-
Page 19
19 W415-0299 / J / 04.14.08 FIGURE 33 FIGURE 31 INST ALLA TION WALL AND CEILING PR O TECTION HORIZONT AL INST ALLA TION VERTICAL INST ALLA TION FIGURE 32 FIGURE 29 Apply a bead of caulking all around and place the fi restop top, so that the vent shield covers the top of the vent within the opening. Place the fi restop bottom against the fi resto[...]
-
Page 20
20 W415-0299 / J / 04.14.08 F or safe and proper operation of the fi replace, follow the vent- ing instructions exactly. Eight (8") inches is the minimum bend radius allowed for the 8" diameter fl exible liner . 1. Stretch the 5" diameter fl ex pipe to the required length tak- ing into account the additional length needed for the [...]
-
Page 21
21 W415-0299 / J / 04.14.08 FIGURE 41 1. Install the 5" diameter fl ex pipe to the fi replace. Secure with 3 screws and fl at washers. Seal the joint and screw holes using high temp sealant (not supplied) or Red RTV Silicone may also be used in this location. 2. Install the 8" diam- eter fl ex pipe to the fi replace. Attach and seal [...]
-
Page 22
22 W415-0299 / J / 04.14.08 Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed. The three-sided top extension piece may be removed if non-combustible framing is faced with a non-combustible material. * SEE FIGURE 44 . FINISHING MINIMUM MANTEL AND ENCLO- SURE CLEARANCES When using[...]
-
Page 23
23 W415-0299 / J / 04.14.08 PHAZER TM logs, glowing and charcoal embers, exclusive to Wolf Steel Ltd. fi replaces, provide a unique and realistic glowing effect that is dif ferent in every installation. T ake the time to carefully position the embers for a maximum glowing effect. Figures 49 A - H. 1 . Looking at the unit from the valve side, place[...]
-
Page 24
24 W415-0299 / J / 04.14.08 L36 LOUVRE INST ALLA TION FIGURE 52 a-c HOOD Attach the hood by pressing the top fl ange into the clips along the top of the louvre opening. Secure using a screw through the centre slot. LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left and right corners of the unit. T o remove the louvres, [...]
-
Page 25
25 W415-0299 / J / 04.14.08 Ensure that the door is proper ly clipped onto the steel lip to pre- v ent o verhea ting, glass breaka ge and / or discolora- tion of the upper trim. T o install the door(s), hook it over the steel lip located above the door opening. Secure with screws along the bottom of the door . T ighten screws snugly . Do not over -[...]
-
Page 26
26 W415-0299 / J / 04.14.08 Remove the "Z" shaped mounting bracket secured to the burner , by the pilot. Remove the thermodisc from the bracket supplied in the blower kit and attach to the mounting bracket. Attach the connectors from the black and white wires to the ther- modisc. Do not overtighten thermodisc or distort housing. Attach th[...]
-
Page 27
27 W415-0299 / J / 04.14.08 • T urn off all gas to the fi replace. • Open windows. • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone. Follow the gas sup- plier's instructions. • If you cannot reach your [...]
-
Page 28
28 W415-0299 / J / 04.14.08 Adjust the pilot screw to provide properly sized fl ame. T urn in a clockwise direction to reduce the gas fl ow . Natural gas models have air shutters set at 1/4 (.250") inch open. Propane gas models have air shutters set at 7/16 (.437) inch open. Closing the air shutter will cause a more yellow fl ame, but can l[...]
-
Page 29
29 W415-0299 / J / 04.14.08 # P ART No. DESCRIPTION 1* W361-0016 GLOWING EMBERS 2* W550-0001 CHARCOAL EMBERS 3* W562-0009 DOOR GASKET (100") 4 W010-0454 GLASS W/ GASKET 5 W010-1778 FIRESTOP 6* W385-0245 NAPOLEON ® LOGO 8 GL-657 BGD40 LOGSET 9 W135-0284 LOG#1 10 W135-0285 LOG#2 1 1 W135-0286 LOG#3 - PIECE A 12 W135-0287 LOG#3 - PIECE B 13 W135[...]
-
Page 30
30 W415-0299 / J / 04.14.08[...]
-
Page 31
31 W415-0299 / J / 04.14.08 # P ART No. DESCRIPTION 1 W690-0001 MILLIVOL T THERMOST A T 2 GD501 HEA T GUARD 3* W573-0007 HI-TEMP SEALANT 4* W010-0370 WALL SUPPORT ASSEMBL Y 5 GZ-550-1KT BLOWER KIT 6* W175-0170 DURA-VENT ZERO CLEARANCE ADAPTOR 7* W500-0033 V ARIABLE SPEED SWITCH WALL MOUNTING PLA TE 8* W660-0010 REMOTE CONTROL - ADV ANTAGE 8* W660-0[...]
-
Page 32
32 W415-0299 / J / 04.14.08 TR OUBLE SHOO TING GUIDE B EFORE A TTEMPTING TO TROUBLESHOOT , PURGE YOUR UNIT AND INITIALL Y LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR OPEN . SYMPTOM PROBLEM TEST SOLUTION Main burner fl ame is a blue, lazy , transparent fl ame. Blockage in vent. - Remove blockage. In really cold conditions, ice buildup [...]
-
Page 33
33 W415-0299 / J / 04.14.08 SYMPTOM PROBLEM TEST SOLUTION Pilot will not light. No spark at pilot burner - Check if pilot can be lit by a match - Check that the wire is connected to the push button igniter . - Check if the push button igniter needs tightening. - Replace the wire if the wire insulation is broken or frayed. - Replace the electrode if[...]
-
Page 34
34 W415-0299 / J / 04.14.08 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name[...]
-