Napoleon Fireplaces GD45-N manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Napoleon Fireplaces GD45-N, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Napoleon Fireplaces GD45-N one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Napoleon Fireplaces GD45-N. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Napoleon Fireplaces GD45-N should contain:
- informations concerning technical data of Napoleon Fireplaces GD45-N
- name of the manufacturer and a year of construction of the Napoleon Fireplaces GD45-N item
- rules of operation, control and maintenance of the Napoleon Fireplaces GD45-N item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Napoleon Fireplaces GD45-N alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Napoleon Fireplaces GD45-N, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Napoleon Fireplaces service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Napoleon Fireplaces GD45-N.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Napoleon Fireplaces GD45-N item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 W415-0100 / D / 01.13.04 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca GAS - DIRECT VENT MILLIVOL T SYSTEM INST ALLA TION AND OPERA TION INSTRUCTIONS FOR LISTED D[...]

  • Page 2

    2 W415-0100 / D / 01.13.04 WARNING • Do not burn wood or other materials in this fireplace. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the fireplace. • Due to high temperature[...]

  • Page 3

    3 W415-0100 / D / 01.13.04 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test[...]

  • Page 4

    4 W415-0100 / D / 01.13.04 FOR YOUR SA TISF ACTION, THIS FIREPLACE HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUAL- ITY! Maximum input is 45,000 BTU/hr for natural gas and 40,000BTU/hr for propane. When the fireplace is installed at elevations above 4,500ft, and in the absence of specific recommendations from the local authority having juris[...]

  • Page 5

    5 W415-0100 / D / 01.13.04 FIGURE 3 • Under extreme vent configurations, allow several min- utes (5-15) for the flame to stabilize after ignition. • Eight (8") inches is the minimum bend radius allowed for the 7" diameter flexib le air liner . When terminating vertically , the vertical rise is a minimum 36 inches and a maximum 40 feet[...]

  • Page 6

    6 W415-0100 / D / 01.13.04 FIGURES 5 40 FT MAX 1 FT MIN 8 FT MAX (1 FT MAX) HORIZONT AL VENT RUN in feet VERTICAL RISE in feet HORIZONT AL VENT RUN in feet VERTICAL RISE in feet Use the venting option charts to calculate vertical rises for horizontal runs between 3 and 20 feet. When calculating maximum run lengths, include 10 feet for each 90° elb[...]

  • Page 7

    7 W415-0100 / D / 01.13.04 FIGURES 8 HORIZONT AL VENT RUN in feet COMBINED VERTICAL RISE in feet COMBINED HORIZON- T AL VENT RUN in feet VERTICAL RISE in feet FIGURES 7 20 FT MAX 1 FT MIN 10 FT MAX (1 FT MAX) 8 FT MAX (2 FT MAX) 34 FT MAX (1 FT MAX) 18 FT MAX (3 FT MAX) 6 FT MAX 1 FT MIN Use this chart to calculate the vertical rise when using a to[...]

  • Page 8

    8 W415-0100 / D / 01.13.04 AIR TERMINAL INST ALLA TIONS * * * * * Recommended to prevent condensation on windows and thermal breakage * * * * * * * * * * I t i s re c o m m e n d e d t o u s e a h e at s h i e l d a n d t o m a x i m i z e t h e d i s t a n c e t o v i n y l cl a d s o f f i t s. *** *** *** *** * * * T h e p e r i s c o p e G D - [...]

  • Page 9

    9 W415-0100 / D / 01.13.04 FIGURE 12 This application occurs when vent- ing through an exterior wall. Having determined the air termi- nal location, cut and frame a hole in an exterior wall with a minimum square or round opening of 9". (As an alternative to framing, a vent pipe shield may be installed, en- suring a 1" clearance to combust[...]

  • Page 10

    10 W415-0100 / D / 01.13.04 6. If more than one length of liner needs to be used to reach the fireplace, couple them together as illustrated. Seal the joints using the same procedure as described in points 2 and 3. The vent system must be supported every 3 feet, for both vertical and horizontal runs. Use Napoleon support W010-0370 or equivalent non[...]

  • Page 11

    11 W415-0100 / D / 01.13.04 Where possible, cover the sides and top edges of the flash- ing with roofing material. 6. Apply a heavy bead of weatherproof caulking 2 inches above the flashing. Slide the storm collar around the air terminal and down to the caulking. Tighten to en- sure that a weather-tight seal between the air terminal and the collar [...]

  • Page 12

    12 W415-0100 / D / 01.13.04 FIGURE 22 The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use W olf S teel vent spacers W615-0033 every 3 feet and either side of each elbow to maintain the minimum 1¼" clearance be- tween the outer and inner vent pipes. Use Wolf S teel sup- port ring assembly W01[...]

  • Page 13

    13 W415-0100 / D / 01.13.04 Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the fireplace. Noncombustible material (brick, stone or ceramic tile) may protrude in these areas. It is not necessary to install a hearth extension with this fireplace system. When roughing in [...]

  • Page 14

    14 W415-0100 / D / 01.13.04 4. Install rigid black pipe, 1/2" type-L copper tubing or , if local codes permit, a 3/8" flex connector and shutoff valve to the gas line and the fireplace gas valve. Seal and tighten securely . An adapter fitting is required between the gas valve and the copper tubing or flex connector . Do not k Do not k Do [...]

  • Page 15

    15 W415-0100 / D / 01.13.04 PHAZER TM logs, exclusive to Napoleon Fireplaces, pro- vide a unique and realistic glowing effect that is different in every installation. Use only certified PHAZER TM logs avail- able from your Napoleon / Wolf S teel Ltd. dealer . POSITIONING THE LOGS IMPROP- ER L Y WILL CAUSE FLAME IMPINGE- MENT AND CARBONING. Position[...]

  • Page 16

    16 W415-0100 / D / 01.13.04 ( T o open the door , the trim must be removed.) When opening the fire viewing door , a simple procedure must be followed in order to not damage the door . First open the valve control door . Next remove the louvres located above the door . The door is se- cured by two latches at the top and an- other two at the bottom. [...]

  • Page 17

    17 W415-0100 / D / 01.13.04 INST ALLA TION TO BE DONE BY A QUALIFIED IN- ST ALLER and must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 C ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFP A 70 NATIONAL ELECTRICAL CODE in the United S tates. The three slots on the blo[...]

  • Page 18

    18 W415-0100 / D / 01.13.04 ELECTRICAL INST ALLA TION TO BE DONE BY A QUALI- FIED INST ALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 C ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFP A 70 NA TIONAL ELECTRICAL CODE in the United S tates. T o safely install the fan,[...]

  • Page 19

    19 W415-0100 / D / 01.13.04 • Turn off all gas to the fireplace. • Open windows. • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. • If you cannot reach your gas s[...]

  • Page 20

    20 W415-0100 / D / 01.13.04 Natural gas models have air shutters set at ¼ (.250") inch open. Propane gas models have air shutters set at 3/8 (.375) inch open. Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner port[...]

  • Page 21

    21 W415-0100 / D / 01.13.04 # P ART N O . DESCRIPTION 1 GL-618 LOG SET COMPLETE 2 W135-0097 EMBER/FRONT BRICK (#8L) 3 W135-0098 EMBER/FRONT BRICK (#8R) 4 W135-0030 LOG # 1 5 W135-0031 LOG # 2 6 W135-0032 LOG # 3 7 W135-0033 LOG # 4 8 W135-0034 LOG # 5 9 W135-0035 LOG # 6 1 0 W135-0036 LOG # 7 1 1* W390-0001 LA TC H 12* W715-0196 TRIM 1 3 W010-0933 [...]

  • Page 22

    22 W415-0100 / D / 01.13.04 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf S teel Ltd.[...]

  • Page 23

    23 W415-0100 / D / 01.13.04 Pilot goes out when the gas knob is re- leased. The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermo- couple has cooled. Allow approximately 60 seconds for the thermocouple to cool. System is not correctly purged. - purge the gas line with the glass door open. Out of prop[...]

  • Page 24

    24 W415-0100 / D / 01.13.04 Exhaust fumes smelled in room, headaches. Fireplace is spilling. - check door seal and relief flap seal. - check for chimney blockage - check that chimney is installed to building code. - room is in negative pressure; increase fresh air supply . Carbon is being deposited on glass, logs or combustion chamber sur- faces. F[...]