A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco ES31PC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco ES31PC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco ES31PC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco ES31PC should contain:
- informations concerning technical data of Pelco ES31PC
- name of the manufacturer and a year of construction of the Pelco ES31PC item
- rules of operation, control and maintenance of the Pelco ES31PC item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco ES31PC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco ES31PC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco ES31PC.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco ES31PC item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ES30PC/ES31PC Esprit ® with Pressurized IOC C311M-L (1/05) ® INST ALLA TION/OPERA TION U.S. Patent D-472.260[...]

  • Page 2

    2 C311M-L (1/05) CONTENTS Section Page IMPORT ANT SAFETY INSTRUCTIONS .................................................................................................. ............................................................................. 5 DESCRIPTION .........................................................................................[...]

  • Page 3

    C311M-L (1/05) 3 GAIN/AGC ................................................................................................................................................................................................................ 34 IR FIL TER MODE (MODELS ES30PCBW18/ES31PCBW18 ONL Y) ...........................................................[...]

  • Page 4

    4 C311M-L (1/05)[...]

  • Page 5

    C311M-L (1/05) 5 IMPORT ANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’ s instructions. 6. Do not install near any heat sources such as radiators, heat registers, stoves, or other[...]

  • Page 6

    6 C311M-L (1/05) DESCRIPTION The ES30PC/ES31PC Esprit Series is designed to protect camera optics and electronics from moisture and airborne contaminants. The system features a receiver , pan and tilt, enclosure, and a pressurized integrated optics cartridge (IOC). The integrated optics cartridge packages an auto focus camera, lens, heater , and se[...]

  • Page 7

    C311M-L (1/05) 7 INST ALLA TION  When installing the ES30PC/ES31PC Esprit ® system, allow for sufficient clearance between the top of the unit and overhead obstructions. This will prevent interference when the enclosure is driven to its maximum elevation of 33 degrees.  Remove the transformer module from the base of the system by loosening t[...]

  • Page 8

    8 C311M-L (1/05)  Route the wires and cables through the center of the Esprit mount. Reinstall the transformer module into the base. The transformer module can be positioned in the mount base in only one orientation.  ES30PC-5/ES31PC-5 Models Only – Set the 120/230 voltage selector switch on the transformer to the appropriate voltage.  C[...]

  • Page 9

    C311M-L (1/05) 9  Tu rn on the power . If the red LED lights, turn off the power and proceed to the next step. If the red LED does not light, refer to the Tr oubleshooting section.  Plug the male Esprit system connector , located on the bottom of the pan and tilt, into the female Esprit system connector locat ed on the transformer module. Ali[...]

  • Page 10

    10 C311M-L (1/05) TXB SERIES TRANSLA TOR BOARD INST ALLA TION (OPTIONAL) Pelco’ s TXB Series allows controllers from other companies to communicate with the Esprit system. To install a TXB Series board, remove the left cover of the pan and tilt. Once the cover is removed, refer to the manual supplied with the translator board to complete the inst[...]

  • Page 11

    C311M-L (1/05) 11 HOW TO REINST ALL THE PAN AND TIL T COVER The pan and tilt covers must be properly seated and have a tight seal all the way around when installed. To reinstall the pan and tilt cover , do the following: 1. Properly position the cover and slide it into place. The sides of the cover must fit under the front and back rain guards of t[...]

  • Page 12

    12 C311M-L (1/05) OPERA TION POWER-UP DISPLA Y When the system is powered up, the selected protocol, revision number , and other information is displayed on the monitor . For e xample, the screen might show the following information: The information displayed depends on the selected protocol (C, D, or P) and the menu selection for power - up mode. [...]

  • Page 13

    C311M-L (1/05) 13 PRESSURIZED INTEGRA TED OPTICS CARTRIDGE The pressurized IOC houses an auto focus camera, lens, heater , and sensors in a self-contained, sealed unit. Dry nitrogen pressurized to 10 psig controls the environment inside the cartridge, eliminating internal condensation and corrosion. Sensors strategically placed inside the pressuriz[...]

  • Page 14

    14 C311M-L (1/05) CURRENT READING MENU The Current Reading menu displays the existing status of temperature, pressure, and dewpoint inside the integrated optics cartridge. An asterisk displayed to the left of a menu item denotes that an alert condition exists. Due to the heat emitted from the electronics of the camera, normal temperature operating [...]

  • Page 15

    C311M-L (1/05) 15 ZONES A zone is a programmed pan area with set boundaries and identifying label. The Esprit system has a maximum of eight zones, each with a 20-character label. Zones can be programmed to blank video when the camera pans into the zone area. If a zone is blanked, the system displays the message, VIDEO BLANK. (Refer to Zone Blank in[...]

  • Page 16

    16 C311M-L (1/05) PROGRAMMING – ES30PC16/ES31PC16 Backlight comp Off Zoom limit x- - Reset camera <Gain/AGC> <Auto iris> Next Exit Camera Menu Line Sync On Line Sync Phase 0 Exit Line Sync Menu Power Up Default Exit Power -Up Menu Wiper Mode Momentary Wiper Dwell <s> 2 Wiper T ime <m> 60 Exit *Wiper Menu Limit Stops Off Se[...]

  • Page 17

    C311M-L (1/05) 17 PROGRAMMING – ES30PC22/ES31PC22 Gain Limit 7 Exit Gain/AGC Menu Auto-iris mode Auto Auto-iris level 66 Auto-iris peak 16 Exit Auto Iris Menu LowLight limit 2 Shutter speed Auto Auto focus mode Auto <Sharpness> <White balance> Prev Exit Next Menu Auto Sharpness On Sharpness 13 Exit Sharpness Menu Auto white bal On R-G[...]

  • Page 18

    18 C311M-L (1/05) PROGRAMMING – ES30PCBW18/ES31PCBW18 Gain Limit 28 Exit Gain/AGC Menu Auto-iris mode Auto Auto-iris level 91 Auto-iris peak 16 Exit Auto Iris Menu LowLight limit 2 Shutter speed Auto Auto focus mode Auto <IR Filter> <Sharpness> <White balance> Prev Exit Next Menu Auto Sharpness Sharpness On Exit Sharpness Menu I[...]

  • Page 19

    C311M-L (1/05) 19 PROGRAMMING ACCESSING MAIN MENU (PRESET 95) Y ou can call up the main menu on your monitor by programming (setting or creating) preset 95 (28 if in 32-preset mode). Programming preset 95 for Pelco’ s controllers varies according to the type of controller you are using. Instructions for progra mming preset 95 are given below for [...]

  • Page 20

    20 C311M-L (1/05) ACK ACT (ACKNOWLEDGE ACTION) If an enivornmental condition inside of the IOC goes outside of the factory set limits (such as “Low Pressure”) then select ACK Alert to activate the alert label behavior . Program ACK Act to establish alert label behavior after alert acknowledgement. The following acknowledge actions are available[...]

  • Page 21

    C311M-L (1/05) 21 ALERT DISPLA Y POSITION Screen positioning of the alert label is user -defined. Positioning options include the following: To set the alert label position: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Alert. 3. Press the Iris Open button to enter the Alert menu. 4. Position the cursor (>[...]

  • Page 22

    22 C311M-L (1/05) ALERT REPEA T Y ou can program how often an ALERT label is repeatedly displayed until it is acknowledged by the system controller . The followi ng settings are available: Constant The ALERT label is continually displayed on the monitor until acknowledged. 15 min off The ALERT label is displayed every 15 minutes for a 15-second dur[...]

  • Page 23

    C311M-L (1/05) 23 <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Backlight comp Off Zoom limit x- - Reset camera <Gain/AGC> <Auto iris> Next Exit Camera Menu LowLight limit Shutter speed Auto Auto focus mode Auto <Sharpness> <White balance&[...]

  • Page 24

    24 C311M-L (1/05) <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Backlight comp Off Zoom limit x- - Reset camera <Gain/AGC> <Auto iris> Next Exit Camera Menu Auto-iris mode Auto Auto-iris level Auto-iris peak Exit Auto Iris Menu AUTO IRIS The follow[...]

  • Page 25

    C311M-L (1/05) 25 <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Backlight comp Off Zoom limit x- - Reset camera <Gain/AGC> <Auto iris> Next Exit Camera Menu LowLight limit Auto Shutter speed Auto Auto focus mode Auto <IR Filter> <Sharpness[...]

  • Page 26

    26 C311M-L (1/05) AUTO SHARPNESS <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Backlight comp Off Zoom limit x- - Reset camera <Gain/AGC> <Auto iris> Next Exit Camera Menu LowLight limit Auto Shutter speed Auto Auto focus mode Auto <Sharpness>[...]

  • Page 27

    C311M-L (1/05) 27 <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile <Zone Blank> <Az/El/Direction> Exit Other Menu Az/El/Direction Set Azimuth Zero Az/El Az/[...]

  • Page 28

    28 C311M-L (1/05) <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile <Zone Blank> <Az/El/Direction> Exit Other Menu Set Azimuth Zero Az/El Az/El Line Directio[...]

  • Page 29

    C311M-L (1/05) 29 <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile <Zone Blank> <Az/El/Direction> Exit Other Menu Az/El/Direction Set Azimuth Zero Az/El Az/[...]

  • Page 30

    30 C311M-L (1/05) <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Backlight comp Off Zoom limit x- - Reset camera <Gain/AGC> <Auto iris> Next Exit Camera Menu NON-SENSITIVE AREA SENSITIVE AREA BACKLIGHT COMPENSA TION There are two backlight compensat[...]

  • Page 31

    C311M-L (1/05) 31 <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile <Zone Blank> <Az/El/Direction> Exit Other Menu Az/El/Direction Set Azimuth Zero Az/El Az/[...]

  • Page 32

    32 C311M-L (1/05) <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile <Zone Blank> <Az/El/Direction> Exit Other Menu Az/El/Direction Set Azimuth Zero Az/El Az/[...]

  • Page 33

    C311M-L (1/05) 33 <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile <Zone Blank> <Az/El/Direction> Exit Other Menu Az/El/Direction Set Azimuth Zero Az/El Az/[...]

  • Page 34

    34 C311M-L (1/05) GAIN LIMIT The gain limit sets the maximum level for the automatic gain control. Increasing the level will increase the signal level and increase the noise level of the picture. To change the gain: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Camera. 3. Press the Iris Open button to enter [...]

  • Page 35

    C311M-L (1/05) 35 <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Backlight comp Off Zoom limit x- - Reset camera <Gain/AGC> <Auto iris> Next Exit Camera Menu LowLight limit Auto Shutter speed Auto Auto focus mode Auto <IR Filter> <Sharpness[...]

  • Page 36

    36 C311M-L (1/05) <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Limit Stops Off Set Man Limits Clear Man Limits Set Scan Limits Clear Scan Limits Exit Limit Stop Menu LIMIT STOPS NOTE: Limit stops are inactive while setting items in the program menu (e.g. azim[...]

  • Page 37

    C311M-L (1/05) 37 LIMIT STOPS MENU The manual pan limit stops can be set at the controller using the Limit Stops menu: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Limit Stop. 3. Press the Iris Open button to enter the Limit Stop menu. 4. Move the cursor to Set Man Limits and press the Iris Open button. PRE[...]

  • Page 38

    38 C311M-L (1/05) Scan Limit Stops When scan limit stops are set, the pan and tilt reverses direction during random, frame, or auto scanning when a limit stop is reached. The manual scan limit stops can be set in one of two ways: At the controller by programming presets 92 and 93 or At the controller by programming the Limit Stops menu PRESETS Refe[...]

  • Page 39

    C311M-L (1/05) 39 <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Line Sync On Line Sync Phase 0 Exit Line Sync Menu LINE SYNCHRONIZA TION If cameras are out of phase with each other , they may produce what appears to be vertical roll when switching between came[...]

  • Page 40

    40 C311M-L (1/05) <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Backlight comp Off Zoom limit x- - Reset camera <Gain/AGC> <Auto iris> Next Exit Camera Menu LowLight limit Shutter speed Auto Auto focus mode Auto <Sharpness> <White balance&[...]

  • Page 41

    C311M-L (1/05) 41 <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile 90 MPH wind Exit Other Menu P ARK TIME MINUTES This feature causes the system to park at preset 1 aft[...]

  • Page 42

    42 C311M-L (1/05) <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile 90 MPH wind Exit Other Menu PA TTERN LENGTH The Esprit can do the following: One full pattern - 1.5, [...]

  • Page 43

    C311M-L (1/05) 43 <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Power Up Default Exit Power -Up Menu POWER-UP MODE This feature lets the dome resume a desired condition following power -up. The menu includes the following choices. • Default – On power -up,[...]

  • Page 44

    44 C311M-L (1/05) <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile 50 MPH wind Exit Other Menu PROPORTIONAL P AN There are two proportional pan modes: On – Enables th[...]

  • Page 45

    C311M-L (1/05) 45 Default Setting <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Backlight comp Off Zoom limit x- - Reset camera <Gain/AGC> <Auto iris> Next Exit Camera Menu RESET CAMERA Resetting the camera returns the settings to their defaults. M[...]

  • Page 46

    46 C311M-L (1/05) <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile 50 MPH wind Exit Other Menu SCAN SPEED The scan speed is adjustable from 1-40 degrees per second. Thi[...]

  • Page 47

    C311M-L (1/05) 47 <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Backlight comp Off Zoom limit x- - Reset camera <Gain/AGC> <Auto iris> Next Exit Camera Menu LowLight limit Auto Shutter speed Auto Auto focus mode Auto <Sharpness> <White bal[...]

  • Page 48

    48 C311M-L (1/05) <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Backlight comp Off Zoom limit x- - Reset camera <Gain/AGC> <Auto iris> Next Exit Camera Menu LowLight limit Shutter speed Auto Auto focus mode Auto <Sharpness> <White balance&[...]

  • Page 49

    C311M-L (1/05) 49 <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile 50 MPH wind Exit Other Menu SPEED PROFILE This feature allows the operator to set the wind speed cond[...]

  • Page 50

    50 C311M-L (1/05) Auto white bal On Red bal level 182 Blue bal level 182 Exit White Balance Menu <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Backlight comp Off Zoom limit x- - Reset camera <Gain/AGC> <Auto iris> Next Exit Camera Menu LowLight lim[...]

  • Page 51

    C311M-L (1/05) 51 <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Wiper Mode Momentary Wiper Dwell <s> 2 Wiper T ime <m> 60 Exit Wiper Menu WIPER MODE There are three wiper settings: Wiper Mode Wiper Dwell Wiper T ime To change the wiper settings: 1.[...]

  • Page 52

    52 C311M-L (1/05) <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile 90 MPH wind <Zone Blank> Exit Other Menu Video Blank Zone 1 Off 2 Off 3 Off 4 Off 5 Off 6 Off 7[...]

  • Page 53

    C311M-L (1/05) 53 <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile <Zone Blank> <Az/El/Direction> Exit Other Menu Set Azimuth Zero Az/El Az/El Line Directio[...]

  • Page 54

    54 C311M-L (1/05) <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Backlight comp Off Zoom limit x- - Reset camera <Gain/AGC> <Auto iris> Next Exit Camera Menu ZOOM LIMIT ES30PC16/ES31PC16 – 16X optical zoom and 10X electronic zoom ES30PC22/ES31PC22[...]

  • Page 55

    C311M-L (1/05) 55 <Camera> <Line Sync> <Power Up> <Wiper> <Limit Stop> <Alert> <Other> ACK Alert Exit MAIN MENU Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile <Zone Blank> <Az/El/Direction> Exit Other Menu Set Azimuth Zero Az/El Az/El Line Directio[...]

  • Page 56

    56 C311M-L (1/05) TROUBLESHOOTING NOTE: The system contains no user -serviceable parts. If there is a problem with your system, it must be returned to Pelco for servicing. Symptom: System does not operate. 1. Check system input voltage. 2. The Esprit system is protected by a resettable overcurrent protective device located in the transformer module[...]

  • Page 57

    C311M-L (1/05) 57 Symptom: No video or poor video 1. Check the video and power connections to the camera. 2. Check for power to the camera from the Esprit system camera power output. 3. Check all coax BNC connectors from the camera to the monitor . 4. Make sure the controller is set for the correct camera-to-monitor viewing combination; for example[...]

  • Page 58

    58 C311M-L (1/05) MAINTENANCE Clean the enclosure window periodically with a mild non-abrasive detergent in water and a soft cloth to help maintain picture clarity . If operating problems are experienced with the system, refer to the T roubleshooting section. WIPER If the window wiper assembly is installed, replace worn or deteriorated wiper blades[...]

  • Page 59

    C311M-L (1/05) 59 00864 2. Open hinge door to the system. Remove the cap screw that secures the wiper board. Unplug the ribbon cable connector . 00866 RIBBON CABLE CONNECTO R CAP SCREW 00865 3. Lift up wiper board and unplug the cartridge power cables. Let board dangle to the side of the enclosure. 4. Lift cartridge out of the enclosure. 00867 PRES[...]

  • Page 60

    60 C311M-L (1/05) APPENDIX NOTE: Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mode. Therefore, the DIP switch settings have no effect on Coaxitron control signals. Table A. Switch Settings for SW1 Switch Setting Baud Rate SW1-1 SW1-2 SW1-3 2400 OFF OFF OFF* 4800 ON OFF OFF* 9600 [...]

  • Page 61

    C311M-L (1/05) 61 Table B. Switch Settings for SW2 NOTE: The Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mode. Therefore, the DIP switches settings have no effect on Coaxitron control signals. Receiver Address Switch Setting P-T ype D-T ype Control Control SW2-1 SW2-2 SW2-3 SW2-[...]

  • Page 62

    62 C311M-L (1/05) Table B. Switch Settings for SW2 (Continued) (Continued on next page) Receiver Address Switch Setting P-T ype D-T ype Control Control SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 – 112 OFF OFF OFF OFF ON ON ON OFF – 113 ON OFF OFF OFF ON ON ON OFF – 114 OFF ON OFF OFF ON ON ON OFF – 115 ON ON OFF OFF ON ON ON OFF – 11[...]

  • Page 63

    C311M-L (1/05) 63 Table B. Switch Settings for SW2 (Continued) Receiver Address Switch Setting P-T ype D-T ype Control Control SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 – 232 OFF OFF OFF ON OFF ON ON ON – 233 ON OFF OFF ON OFF ON ON ON – 234 OFF ON OFF ON OFF ON ON ON – 235 ON ON OFF ON OFF ON ON ON – 236 OFF OFF ON ON OFF ON ON ON [...]

  • Page 64

    64 C311M-L (1/05) SPECIFICA TIONS ELECTRICAL Input V oltage: 24, 120, or 230 V AC, 50/60 Hz; switch selectable for 120/230 VAC inputs. Reset featur e enabled when power becomes unstable or interrupted. Power Requirements: Maximum power consumption is 70 V A per system Heater and Defroster: Thermostatically controlled heater consumes 10 watts and cy[...]

  • Page 65

    C311M-L (1/05) 65 Sensitivity ES30PC16/ES31PC16: 0.05 lux at 1/2-second shutter speed (NTSC) 0.05 lux at 1/1.5-second shutter speed (P AL) ES30PC22/ES31PC22: 0.02 lux at 1/2-second shutter speed (NTSC) 0.02 lux at 1/1.5-second shutter speed (P AL) ES30PCBW18/ES31PCBW18: 0.08 lux at 1/2-second shutter speed (color , NTSC/P AL) 0.3 lux at 1/1.5-secon[...]

  • Page 66

    66 C311M-K (9/04)[...]

  • Page 67

    REVISION HISTORY Manual # Date Comments C311M 6/01 Original version. C311M-A 8/02 Camera modifications. C311M-B 9/02 Revised per ECO #02-8063. C311M-C 11/02 Revised installation instructions for addition of alignment label. C311M-D 6/03 Added Az/El/Direction menu per ECO #03-8861. Updated to new format. C311M-E 8/03 Revised per ECO #03-9210 for new[...]

  • Page 68

    W orldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 ® United States | Canada | United Kingdom | The Netherlands | Singapore | Spain | Scandinavia | France | Middle East[...]