A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Pitco Frialator 14, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pitco Frialator 14 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Pitco Frialator 14. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Pitco Frialator 14 should contain:
- informations concerning technical data of Pitco Frialator 14
- name of the manufacturer and a year of construction of the Pitco Frialator 14 item
- rules of operation, control and maintenance of the Pitco Frialator 14 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pitco Frialator 14 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pitco Frialator 14, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pitco Frialator service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pitco Frialator 14.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Pitco Frialator 14 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Installation, Operation & Service Instructions Covering Gas Fired Deep Fryers Model Numbers: 35C+, 7, 14, 18, 24, 34, 12, 14R, PR14, PM14, RPB14 with all options P.O.Box 501, 509 Rt 3A, Bow, NH 03302 USA Tel # (603)225-6684 Fax # (603)225-8497 A Blodgett Company[...]
-
Page 2
L20-103 Rev 00 (29 July 1995) WARNING Do NOT attempt to make adjustments to sealed devices. hey are set at the factoryand DO NOT require further adjustments. NOTICE Installation should only be done by a Competent Service Technician. The Model & Serial Number, and the Gas Type & Pressure are stamped into the Data Plate, located on the inside[...]
-
Page 3
TABLES: LP NAT 34 LP NAT 24 LP NAT 12 YES 0.97 24.2 26.3 2.18 19 I3P 37/50 G31 LP YES 2.5 23.6/19.3 26.3/21.4 4.4 6.8 I2Esi 20/25 G20/G25 NAT RPB14B YES 0.86 21.4 23.2 2.18 15.3 I3P 37/50 G31 LP YES 2.2 20.9/16.8 23.2/10.6 4.16 6.2 I2Esi 20/25 G20/G25 NAT RPB14A NO 1.31 33 35.7 LP16 1.4 I3P 37 G31 LP NO 3.31 32.2 35.7 N22 4 X 1.1 I2E+ 20/25 G20/G25[...]
-
Page 4
LP NAT 34 LP NAT 24 LP NAT 12 YES 0.97 24.2 26.3 2.18 19 I3P 37/50 G31 LP YES 2.5 23.6/19.3 26.3/21.4 4.4 6.8 I2Esi 20/25 G20/G25 NAT RPB14B YES 0.86 21.4 23.2 2.18 15.3 I3P 37/50 G31 LP YES 2.2 20.9/16.8 23.2/10.6 4.16 6.2 I2Esi 20/25 G20/G25 NAT RPB14A NO 1.31 33 35.7 LP16 1.4 I3P 37 G31 LP NO 3.31 32.2 35.7 N22 4 X 1.1 I2E+ 20/25 G20/G25 NAT (PM[...]
-
Page 5
8 Filtering Systems ............................................ 8 Frying Systems .............................................. 8 TROUBLESHOOTING: ............................................... 7 UFM or Built In Filter Operation ................................... 7 Basket Lifts ................................................ 7 Float Switch ....[...]
-
Page 6
14 Table of Schematic Contents ..................................... 13 Table of Schematic Descriptions .................................. 13 SCHEMATICS: ..................................................... 13 RPB Machines .............................................. 12 Electronic Ignition Option ....................................... 12 Comput[...]
-
Page 7
MODEL NUMBER RECOGNITION: EXPLANATION OF MODEL NUMBER CONFIGURATION: Most model numbers have a PREFIX and a SUFFIX. The explanation of the different Prefixes and Suffixes is listed below. Standard fryers, with NO options and a mild steel tank, will not have any PREFIX or SUFFIX but simply have a number (7, 14, 18 etc.) EXPLANATION OF PREFIXES WITHI[...]
-
Page 8
INITIAL ASSEMBLY: Remove the two (2) screws that mount the rear of the tank to the cabinet. Place the Flue Heat Deflector in place with the bend facing forward. Replace the tank mounting screws, through the Flue Heat Deflector into the tank. In some cases the fryers legs may need to be installed. ELECTRICAL CONNECTIONS: (Some machines do not requir[...]
-
Page 9
NOTE: On machines equipped with Digital Controls or Computers that are programmed with a melt cycle, the main burners will pulse on and off to slowly heat the oil. When the oil temperature has reached a preset level the main burners will run constantly until the set temperature has been reached. FILTERING: Filtering is recommended on a daily basis [...]
-
Page 10
OPERATING THE COMPUTER CONTROL: To check the ACTUAL Temperature Press the key (After 5 seconds the display will return to the run mode.) To check the SET Temperature Press the key two times. (After 5 seconds the display will return to the run mode.) To check the COOK, SHAKE or HOLD times press the key and the desired PRODUCT NUMBER key. (The times [...]
-
Page 11
CLEANING / MAINTENANCE: DAILY CLEANING: Using a soft cloth and a mild detergent, wipe all external surfaces until they are free of debris. It is permissible to allow a thin film of cooking oil to remain on all exposed (NON PAINTED) surfaces. Be sure to clean the front panel and behind the door. WEEKLY CLEANING: Turn the gas valve knob to the PILOT [...]
-
Page 12
TROUBLESHOOTING: FRYING SYSTEM: Should there be a problem with your machine, the following checks should be done prior to calling an Authorized Service Company. Make sure the machine is operated correctly and that the Computer or Digital Display (when installed) is programmed accordingly. Make sure the pilot is lit Check pilot Check for blown fuses[...]
-
Page 13
FILTERING SYSTEM: Check quick disconnect Check pick up tube is attached correctly Check paper installation Check pick up screen installation Filter pump running Check power to machine Check circuit breaker Check motor overheat trip Filter pump NOT running Check the small screen in the end of the pick up tube (Inside the large steel nut.) to make su[...]
-
Page 14
Hi Limits Thermostats: All Hi Limits are electric switches that OPEN at a pre determined temperature. Check for continuity across the terminations when the wires are disconnected. Thermocouples: Use a Multi Meter capable of measuring DC voltage below 1V. Attach the Negative lead to the Pilot Bracket and the Positive lead to the upper connection at [...]
-
Page 15
connections for integrity If the connection is good the Probe should be checked as described in the appropriate section. If the Probe is not at fault the computer may be suspect. { If the display is lit but the Main Burners are still controlled by the Alternate Thermostat, check for 24 vdc at the K5 relay. This relay is the Control Transfer Relay a[...]
-
Page 16
TROUBLE SHOOTING: Before diagnosing any machine for defective components check the following items: v Check all power cords and appropriate circuit breakers to ensure that electrical power is supplied to the machine. v Check all machine gas shut off valves to ensure that gas is supplied to the machine. v Check all machine fuses. v Check any appropr[...]
-
Page 17
Defective HSI. Defective HSI module. Machine makes Booming sound. Defective Blower Relay. Defective Blower. Burners try to ignite but Blower does NOT come on. Defective HSI module. Defective HSI. Defective Burner. Incorrect Gas or Air pressure. Burners come ON but shut down after a few seconds. Defective HSI module. HSIs blow but Burners do NOT com[...]
-
Page 18
PARTS LIST: RPB, LP Gas Gas Valve V1 RPB, Nat Gas Gas Valve V1 Electronic Ignition, LP Gas Gas Valve V1 Electronic Ignition, Nat Gas Gas Valve V1 Non Electronic Ignition, LP Gas Gas Valve V1 Non Electronic Ignition, Nat Gas Gas Valve V1 PP10429 Transformer T2 PP10210 Transformer T1 PP10837 Hi Limit Thermostat S7 P5047169 Basket Lift Micro Switch S5[...]