Keating Of Chicago Custom Pasta Gas System 0107 manual
- Read online or download the manual
- 26 pages
- 0.52 mb
Go to page of
Similar user manuals
-
Pasta Maker
Keating Of Chicago Gas Custom Pasta System
26 pages 1.41 mb -
Pasta Maker
Keating Of Chicago 2009
25 pages 1.12 mb -
Pasta Maker
Keating Of Chicago Pasta Baskets
2 pages 0.21 mb -
Pasta Maker
Keating Of Chicago 240V
23 pages 1.57 mb -
Pasta Maker
Keating Of Chicago 0107
26 pages 0.5 mb -
Pasta Maker
Keating Of Chicago 24763
26 pages 1.79 mb -
Pasta Maker
Keating Of Chicago Custom Pasta Gas System 0107
26 pages 0.52 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Keating Of Chicago Custom Pasta Gas System 0107, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Keating Of Chicago Custom Pasta Gas System 0107 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Keating Of Chicago Custom Pasta Gas System 0107. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Keating Of Chicago Custom Pasta Gas System 0107 should contain:
- informations concerning technical data of Keating Of Chicago Custom Pasta Gas System 0107
- name of the manufacturer and a year of construction of the Keating Of Chicago Custom Pasta Gas System 0107 item
- rules of operation, control and maintenance of the Keating Of Chicago Custom Pasta Gas System 0107 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Keating Of Chicago Custom Pasta Gas System 0107 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Keating Of Chicago Custom Pasta Gas System 0107, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Keating Of Chicago service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Keating Of Chicago Custom Pasta Gas System 0107.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Keating Of Chicago Custom Pasta Gas System 0107 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
CUST OM P AST A ™ SYSTEM GAS SER VICE MANU AL KEEP THIS MANU AL FOR TRAINING NEW PERSONNEL 1-800-KEA TING www .keatingofchicago.com ON OFF 100° 2 2 0 ° O F F 200° 1 2 0 ° 1 4 0 ° 1 6 0 ° 1 80 ° 100° 2 2 0 ° O F F 200° 1 2 0 ° 1 4 0 ° 1 6 0 ° 1 80 ° P I L O T T O L I T E 3 0 S E C . H O L D M U S T B E O N F O R P I L O T O F F O N M[...]
-
Page 2
i T his operating, inst allation, and service manual should be given to the user . The operator of the Pasta System should be familiar with the functions and operation of the cooker . This manual must be kept in a prominent, easily reac hable location near the Past a System. P OST T H I S L AB E L I N A P R O M I N E NT LO CA T I O N O N Y O UR UNI[...]
-
Page 3
T ABLE OF CONTENTS SECTION I INTRODUCTION General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 S tandard Features . . . . . . . . . . . . . . . . . . . . . . . . . .1 Model V ariations . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . .1-3 SECTION II INST [...]
-
Page 4
I INTRODUCTION GENERAL Keating Pasta Gas Systems are designed to give maximum production efficiency , delivering high quality food products. The following design features are incorporated in Keating Pasta Gas Systems. ST ANDARD FEA TURES l Highly polished stainless steel vessel l Highly polished stainless steel front l Highly polished stainless ste[...]
-
Page 5
l Y ou must maintain this appliance free and clear from combustibles. l Y ou must maintain the following minimum clearances from combustible and noncombustible construction: l Adequate clearance for servicing and proper operation must be maintained. Y our Pasta System is designed to be serviced from the front. l Keating commercial Pasta Systems are[...]
-
Page 6
IF NOT INST ALLED, OPERA TED AND MAINT AINED IN ACCORDANCE WITH THE MANUF ACTURER’S INSTRUCTIONS, THIS PRODUCT COULD EXPOSE YOU TO SUBST ANCES IN FUEL OR IN FUEL COMBUSTION WHICH CAN CAUSE DEA TH OR SERIOUS ILLNESS AND WHICH ARE KNOWN T O THE ST A TE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. II INST ALLA TION This P[...]
-
Page 7
4 Figure 2-1 RESTRAINING DEVICES On Pasta System inst allations with casters, casters and jam nuts must be completely tightened. Adequate means must also be provided to limit the movement of the appliance without depending on the connector , the quick-disconnect device or its associated piping to limit the appliance movement. Connectors must comply[...]
-
Page 8
5 A 3 / 4 " IPS manual gas valve is shipped with each single Pasta System for field inst allation. Batteries have a factory installed manual gas valve for each Past a System. The required gas pressure for proper operation of each Pasta System is 4" water column (WC) for natural gas and 10” water column (WC) for Propane gas at the burner[...]
-
Page 9
6 Constructional changes to the area where the Pasta System is installed shall not af fect the air supply to the Pasta System. The installation, st art-up and changes required when changing from one gas type to another can be performed only by a certified professional. The Pasta System is intended only for commercial use and is to be operated only [...]
-
Page 10
2. T urn “On” main power On/Off switch (located between the amber and green indicating lights). 3 . Light the constant pilot (located next to lef t burner as you face it). If your Pasta System has an optional spark ignitor , omit this step. 4. Activate pilot light momentary switch (let top corner) and hold about 30 seconds, releasing it after p[...]
-
Page 11
1. T urn off Pasta System and open the door . Figure 3-3 Drain, drain valve and overflow tubing 2. Slowly turn handle. The drain valve will be completely open after 1 / 4 turn. CLEANING When cleaning and boiling out your Pasta System, use white vinegar and Keating Klenzer to keep your Pasta System in top condition. Once your Pasta System vessel is [...]
-
Page 12
B. How to program the “Keating” Electronic Timer l The Keating Electronic T imer is programmable to four different timer ranges with two dif ferent alarm modes for each time range. l The timers are shipped from the factory preset to program 5: Minutes : seconds (00:01 to 59:59) with continuous alarm l T o program another time range or alarm mod[...]
-
Page 13
10 PREVENTIVE MAINTENANCE Preventive maintenance should be done in daily , weekly , monthly and yearly intervals as necessary . Following preventive maintenance procedures will help keep your Pasta System working ef ficiently . Proper care and servicing will lead to years of quality performance. ¥ ¥ NOTE: The most important part of any maintenanc[...]
-
Page 14
in the tube on the right side of the overflow deck. The upper sensor controls the water level and the lower sensor controls the low water safety shut-off system. Once the water On/Off switch is turned on, the blue light will come on and start to fill until the water level reaches the upper sensor . The burners will not come on until the water level[...]
-
Page 15
12 PROBLEM PROBABLE CAUSE SOLUTION Constant pilot won’t light. a. Gas isn't turned on. b. Clogged constant pilot tubing. c . Constant pilot valve isn't turned on. a. T urn manual gas valve on. If using flexible connector with quick disconnect, make sure quick disconnect is completely engaged. b. T urn Custom Pasta System and manual gas [...]
-
Page 16
13 PROBLEM PROBABLE CAUSE SOLUTION Flames come out front. a. Burners misaligned. b. Exhaust problems. c. Radiants have slipped forward. d. Flue blockage. a. Adjust position of burners. b. Install deflector to block down draf t. Install or adjust flue restrictors. If problem persists, cont act your HV AC representative. c. Reposition radiants. d. T [...]
-
Page 17
14 PROBLEM SOLUTIONS (Follow Sequentially) W ater always filling. a. Clean sensors thoroughly with brush and vinegar . b. Adjust the sensitivity of the B Board (for the top sensor) fully clockwise. c. If filling persists, ground out the top sensor (if filling stop s, replace sensor – Part #010212). d. If filling persists after grounding out the s[...]
-
Page 18
15 REPLACEMENT OF A AND B BOARDS 1. Locate the wiring diagram. it will help later with connecting wires to the board. 2. Disconnect wires from the board. 3 . Unscrew mounting screws. There are three of them per board. 4. Replace the board. 5. Reconnect the wires. 6. Adjust sensitivity . 7. Close the box. 8. Seal the box using silicone and filling a[...]
-
Page 19
16 CUSTOM P AST A ™ SYSTEM CONTROL P ANEL WITH DIGIT AL TIMERS VII P ARTS LISTS ORDERING P ARTS P arts may be ordered by p art number by calling Keating at 1-800-KEA TING or your service company . Y ou may also order online at the Keating Parts S tore, www .keatingofchicago.com. Refer to the Keating Custom Pasta ™ System Limited W arranty for c[...]
-
Page 20
17 ITEM DESCRIPTION QUANTITY P ART NUMBER 1 TOGGLE SWITCH - PILOT ON 1 004507 2 INDICA TING LIGHT , AMBER - PILOT ON 1 031624 3 TOGGLE SWITCH – MAIN ON-OFF 1 004501 4 INDICA TING LIGHT , GREEN - SECONDARY BURNER ON 1 009375 5 UNUSED 3 ------ 6 DIGIT AL TIMER(S) 2 056921 7 THERMOST A T 2 031466 8 DIAL PLA TE 2 034975 9 THERMOST A T KNOB 2 004163 1[...]
-
Page 21
18 GAS P AST A SYSTEM ASSEMBL Y I ITEM DESCRIPTION MODELS P ART# 14 18 20 24 1 GAS V AL VE, 120V ALL NA TURAL GAS 004269 1 1 1 1 LP 008123 1 1 1 1 2 RUNNER PILOT TUBE SEE BELOW 1 1 1 1 3 CONST ANT PILOT ASSEMBL Y ALL (1.8"X28") 004259 1 1 1 1 4 CONST ANT PILOT V AL VE ALL 004266 1 11 1 5 RUNNER PILOT GAS COCK STRAIGHT (W/005743) ALL 01540[...]
-
Page 22
19 ITEM DESCRIPTION MODELS P ART# 14 18 20 24 22 RADIANT , 2 - FINS ALL 000041 3 4 4 5 23 BURNER 008264 2 2 2 3 BURNER CM 004088 2 24 SECONDAR Y BURNER ALL 004088 1 2 2 2 25 SECONDAR Y GAS SOLENOID ALL 037033 1 2 2 2 26 P AST A VESSEL CALL 1-800-KEA TING 1 1 1 1 27 W A TER LEVEL SENSORS ALL 010212 2 2 2 2 28 DRAIN V AL VE, FRONT , 1" 016345 1 [...]
-
Page 23
20 P AST A SYSTEM WIRING DIAGRAM[...]
-
Page 24
21 GAS P AST A SYSTEM WITH BASKET -LIFT WIRING DIAGRAM[...]
-
Page 25
L IMITED W ARRANTY Keating Of Chicago, Inc. ("Keating”) warrants to the original purchaser . ("Customer"), all new Keating Fryers, Filter Systems, Griddles, Keep Krisp ® , Custom Pasta Systems, T op-Side™ Cookers, Computer T imers, Fryer & Pasta V essels, and Keating replacement parts ("products") installed after J[...]
-
Page 26
K EA TI N G LI M ITE D W AR RANTY C AR D PLEASE COMPLETE AND MAIL A T ONCE–WARRANTY IS NOT IN EFFECT UNTIL CARD IS RETURNED COMP ANY : ____________________________________________________________________________________________________ ADDRESS: ____________________________________________________________________________________________________ CI[...]